{"name":"Physiologic Instruments Inc","category":{"key":"retail","label":"Shops & Retail"},"summary":"Physiologic Instruments designs Ussing Chamber Systems, voltage/current clamps, and data tools for epithelial transport & CFTR research worldwide.","about":"EasyMount Chamber Slider Inserts provide a precise, secure way to mount tissue or cell-culture membranes for Ussing chamber experiments. Each insert is engineered for perfect alignment inside our EasyMount systems—simply load your sample, slide it into place, and lock it down. The result is a consistent, leak-free seal and reliable measurements every time, making sample setup fast, repeatable, and lab-friendly. Unlock the power of precise epithelial barrier research with Physiologic Instruments and our EasyMount Ussing Chamber Systems.","website":"https://physiologicinstruments.com/","contact":{"phone":null,"email":"office@piusa.net","contactPage":"https://physiologicinstruments.com/pages/contact"},"location":{"address":null,"city":"Venice","region":"Florida","postalCode":null,"country":"United States","geo":null,"areaServed":[],"mapUrl":null,"timeZone":null},"hours":[],"openingHoursSpecification":[],"priceRange":null,"cuisine":null,"services":[{"name":"Details","description":null},{"name":"Recently Viewed Products","description":null},{"name":"EasyMount Chamber Details","description":null},{"name":"EasyMount Ussing Chambers - Model: P2300","description":"The EasyMount Ussing Chamber - model P2300, is designed for researchers conducting advanced studies on animal tissues and cell cultures. This chamber offers a streamlined solution for mounting tissues or permeable membrane supports, support"},{"name":"Care and Feeding Instructions for the EasyMount Ussing Chambers","description":null}],"priceList":[{"name":"P2023-100 Electrode Tips","price":"$95"},{"name":"P2020-S Electrode Set (2 Voltage & 2 Current)","price":"$223"},{"name":"P2020-VS Electrode Set (4 Voltage)","price":"$256"},{"name":"P2020-IS Electrode Set (4 Current)","price":"$174"},{"name":"EasyMount Ussing Chamber - Model P2300","price":"$703"}],"faqs":[{"question":"Product Search..","answer":"Popular Search Terms Ussing Chamber Ussing Chamber Systems ussing chamber sliders voltage current clamps Ussing Systems ussing chamber system transepithelial solute transport EpiStat cystic fibrosis electrophysiology ussing chamber"},{"question":"1. How are Ussing chambers used to measure nutrient absorption in fish feed research?","answer":"Answer: Ussing chambers measure how nutrients like glucose, amino acids, and ions move across isolated fish intestinal tissue. Researchers mount a section of gut between two fluid-filled halves—one simulating the intestinal lumen and the other the bloodstream. By monitoring changes in electrical current (short-circuit current) and transepithelial voltage, they can detect active nutrient transport. This allows aquafeed developers to quantify how efficiently ingredients such as plant proteins, fishmeal alternatives, or additives are absorbed by the fish intestine."},{"question":"2. Why is intestinal barrier integrity important when developing new aquafeed formulations?","answer":"Answer: A healthy intestinal barrier prevents harmful bacteria, toxins, and large molecules from entering the bloodstream while allowing nutrients to pass through. If a feed ingredient weakens the barrier—detected as a drop in transepithelial electrical resistance (TER) in Ussing chamber tests—it may increase stress, inflammation, or disease susceptibility. Conversely, feeds that maintain or improve TER values indicate better gut health and nutrient utilization. For feed manufacturers, verifying intestinal integrity is crucial for both fish welfare and feed performance."},{"question":"3. What kinds of nutrients or ions can Ussing chambers measure in aquaculture species?","answer":"Answer: Researchers can measure uptake of sugars (glucose, fructose), amino acids (alanine, lysine, glutamine), peptides, minerals (phosphate, calcium), and ions such as sodium and chloride. Each nutrient’s transport is associated with specific ion currents that the Ussing chamber’s electrodes detect. Some studies also use radiotracers or fluorescent markers for precise quantification. This flexibility makes Ussing chambers one of the most comprehensive tools for evaluating nutrient bioavailability across species like salmon, tilapia, and sea bream."},{"question":"4. Can Ussing chamber data replace in vivo digestibility or feeding trials?","answer":"Answer: Not entirely—Ussing chamber studies complement, not replace, in vivo work. Chambers provide ex vivo, tissue-level insights into transport rates and barrier function, allowing researchers to screen ingredients or additives before committing to full-scale feeding trials. This step reduces costs, shortens development time, and limits live-animal use. Once promising candidates are identified, traditional digestibility trials confirm growth and feed conversion outcomes."},{"question":"5. How do researchers prepare fish intestinal tissue for Ussing chamber experiments?","answer":"Answer: After euthanizing the fish humanely, the intestine is dissected, rinsed with saline, and cut into flat sections suitable for mounting. The tissue must remain viable—oxygenated and kept at species-appropriate temperature and salinity. Each section is clamped between two halves of the chamber, exposing the inner (luminal) and outer (serosal) sides to controlled solutions. This setup preserves natural ion gradients and transport processes for accurate measurement."},{"question":"6. What diseases or genetic factors can Ussing chambers help investigate in fish?","answer":"Answer: Ussing chambers help reveal how diseases or genetic variations affect nutrient absorption. For example, intestinal inflammation, parasitic infections, or stress can reduce transporter activity and lower TER values. Likewise, genetic lines bred for faster growth may show higher active transport of glucose or amino acids. By comparing tissues across conditions, researchers can isolate the physiological mechanisms behind performance differences."},{"question":"7. How do feed additives like enzymes or omega-3 fatty acids influence nutrient absorption in Ussing chamber studies?","answer":"Answer: Feed additives can either enhance or impair intestinal transport. Enzymes and probiotics may improve amino acid uptake and barrier integrity, while excessive fats or poorly emulsified omega-3 sources might temporarily reduce absorption efficiency. Using Ussing chambers, scientists can expose intestinal tissue to feed extracts with and without these additives and directly measure how transport currents or TER values change—providing evidence for optimal inclusion levels."},{"question":"8. What is the typical duration of an Ussing chamber experiment in fish nutrition research?","answer":"Answer: Most fish tissue experiments run between one and three hours. The protocol typically includes an equilibration phase (20–30 minutes), baseline readings, sequential substrate additions (e.g., glucose, amino acids), and inhibitor tests. TER and ion flux are recorded continuously. Tracer studies may extend slightly longer to capture steady-state fluxes. Multi-channel systems, like Physiologic Instruments’ EasyMount rigs, allow several tissues or diets to be tested simultaneously."},{"question":"9. Which fish species are most commonly studied with Ussing chamber systems?","answer":"Answer: Ussing chamber methods have been validated for many aquaculture species including Atlantic salmon, rainbow trout, European sea bream, sea bass, tilapia, carp, and catfish. The technique is adaptable—chamber temperature, saline composition, and tissue segment (proximal or distal intestine) are adjusted to each species’ physiology. The same core principles apply across marine and freshwater fish."},{"question":"10. How can aquafeed manufacturers integrate Ussing chamber data into product development?","answer":"Answer: Feed manufacturers use Ussing chamber data to identify which formulations truly improve absorption and gut integrity before expensive grow-out trials. Data such as ΔIsc (transport change) and TER stability guide ingredient selection, enzyme inclusion, and processing choices. By linking these physiological metrics with digestibility and growth data, companies can market products backed by quantifiable “bioavailability performance,” differentiating themselves in a competitive aquafeed market."}],"rating":null,"features":[],"paymentMethods":["iDEAL"],"languages":["English","German","Italian","Spanish","Chinese"],"foundingYear":"1981","registration":{"companyNumber":null,"vatNumber":null},"shop":{"platform":"Shopify","status":"open","currency":"USD","categories":["EasyMount Ussing Chamber Sliders","P2300 EasyMount Ussing Chambers Slider Inserts","EasyMount Ussing Chamber Components","P2400 Low Volume EasyMount Sliders","Accessories","Ussing Chamber Systems","Voltage Current Clamp","Ussing Chambers","P2250 EasyMount Ussing Chambers Slider Inserts"],"priceRange":{"min":223,"max":365,"currency":"USD","text":"$223–$365","sampled":49},"priceNote":null,"productCount":82,"productsUpdatedAt":"2026-11-25T14:51:47.000Z","productsSyncedAt":"2026-11-25T14:51:47.733Z","productsChangedAt":"2026-11-25T14:51:47.733Z","shipping":{"countries":["Worldwide"],"deliveryTime":null,"freeShippingFrom":null,"page":null},"returns":{"period":null,"page":null},"reviews":[],"trustMarks":[],"products":[{"name":"P2413 EasyMount Ussing Chamber Slider","url":"https://physiologicinstruments.com/products/p2413-easymount-ussing-chamber-slider","image":"https://cdn.shopify.com/s/files/1/0653/7530/5944/products/P2413_Ussing_Chamber_Slider_Insert.jpg?v=1736970420","price":223,"priceMax":null,"currency":"USD","priceText":"$223","availability":"in stock","category":"EasyMount Ussing Chamber Sliders","brand":"Physiologic Instruments","description":"P2413 EasyMount Low Volume Ussing Chamber Slider for Rat Intestine or Bladder APETURE SIZE: 9.5MM | Area = 0.71 cm 2 The P2413 EasyMount Low Volume Ussing Chamber slider is a specialized tissue holder designed for use with the EasyMount Uss","updatedAt":"2026-11-25T14:51:47.000Z"},{"name":"P2412 EasyMount Ussing Chamber Slider","url":"https://physiologicinstruments.com/products/p2412-easymount-ussing-chamber-slider","image":"https://cdn.shopify.com/s/files/1/0653/7530/5944/products/P2412_Ussing_Chamber_Slider_Insert.jpg?v=1736970419","price":223,"priceMax":null,"currency":"USD","priceText":"$223","availability":"in stock","category":"EasyMount Ussing Chamber Sliders","brand":"Physiologic Instruments","description":"P2412 EasyMount Low Volume Ussing Chamber Slider for Rat Intestine or Bladder APETURE SIZE: 8.0MM | Area = 0.50 cm 2 The P2412 EasyMount Low Volume Ussing Chamber slider is a specialized tissue holder designed for use with the Low Volume Ea","updatedAt":"2026-11-25T14:51:47.000Z"},{"name":"P2411 EasyMount Ussing Chamber Slider","url":"https://physiologicinstruments.com/products/p2411-easymount-ussing-chamber-slider","image":"https://cdn.shopify.com/s/files/1/0653/7530/5944/products/P2411_Ussing_Chamber_Slider_Insert.jpg?v=1736970417","price":223,"priceMax":null,"currency":"USD","priceText":"$223","availability":"in stock","category":"EasyMount Ussing Chamber Sliders","brand":"Physiologic Instruments","description":"P2411 EasyMount Low Volume Ussing Chamber Slider for Rat Intestine or Bladder APETURE SIZE: 6.2MM | Area = 0.30 cm 2 The P2411 EasyMount Low Volume Ussing Chamber slider is a robust tissue holder crafted for use with the EasyMount Ussing Ch","updatedAt":"2026-11-25T14:51:47.000Z"},{"name":"P2410 EasyMount Ussing Chamber Slider","url":"https://physiologicinstruments.com/products/p2410-easymount-ussing-chamber-slider","image":"https://cdn.shopify.com/s/files/1/0653/7530/5944/products/P2410_Ussing_Chamber_Slider_Insert.jpg?v=1736970416","price":223,"priceMax":null,"currency":"USD","priceText":"$223","availability":"in stock","category":"EasyMount Ussing Chamber Sliders","brand":"Physiologic Instruments","description":"P2410 EasyMount Low Volume Ussing Chamber Slider for Mouse Intestine or Bladder APETURE SIZE: 5.0MM | Area = 0.20 cm 2 The P2410 EasyMount Low Volume Ussing Chamber slider is a specially designed tissue holder in the EasyMount Ussing Chambe","updatedAt":"2026-11-25T14:51:47.000Z"},{"name":"P2409 EasyMount Ussing Chamber Slider","url":"https://physiologicinstruments.com/products/p2409-easymount-ussing-chamber-slider","image":"https://cdn.shopify.com/s/files/1/0653/7530/5944/files/P24XX-Image-Coming-Soon.jpg?v=1736970415","price":340,"priceMax":null,"currency":"USD","priceText":"$340","availability":"in stock","category":"EasyMount Ussing Chamber Sliders","brand":"Physiologic Instruments","description":"P2409 EasyMount Low Volume Ussing Chamber Slider for Mouse Intestine or Bladder APETURE SIZE: 4.0MM | Area = 0.126 cm 2 The P2409 EasyMount Low Volume Ussing Chamber slider is a specialized tissue holder designed for use with the EasyMount","updatedAt":"2026-11-25T14:51:47.000Z"},{"name":"P2408B EasyMount Ussing Chamber Slider","url":"https://physiologicinstruments.com/products/p2408b-easymount-ussing-chamber-slider","image":"https://cdn.shopify.com/s/files/1/0653/7530/5944/products/P2408A_Ussing_Chamber_Slider_Insert.jpg?v=1736970413","price":248,"priceMax":null,"currency":"USD","priceText":"$248","availability":"in stock","category":"EasyMount Ussing Chamber Sliders","brand":"Physiologic Instruments","description":"P2408B EasyMount Low Volume Ussing Chamber Slider for Extremely Small Tissues APETURE SIZE: 1.0MM | Area = 0.008 cm 2 The P2408B EasyMount Low Volume Ussing Chamber slider is a precision-engineered tool within the EasyMount Ussing Chamber s","updatedAt":"2026-11-25T14:51:47.000Z"},{"name":"P2408A EasyMount Ussing Chamber Slider","url":"https://physiologicinstruments.com/products/p2408a-easymount-ussing-chamber-slider","image":"https://cdn.shopify.com/s/files/1/0653/7530/5944/products/P2408A_Ussing_Chamber_Slider_Insert.jpg?v=1736970413","price":248,"priceMax":null,"currency":"USD","priceText":"$248","availability":"in stock","category":"EasyMount Ussing Chamber Sliders","brand":"Physiologic Instruments","description":"P2408A EasyMount Low Volume Ussing Chamber Slider for Extremely Small Tissues APETURE SIZE: 0.5MM | Area = 0.002 cm 2 The P2408A EasyMount Low Volume Ussing Chamber slider is a precision-engineered tool within the EasyMount Ussing Chamber s","updatedAt":"2026-11-25T14:51:47.000Z"},{"name":"P2408 EasyMount Ussing Chamber Slider","url":"https://physiologicinstruments.com/products/p2408-easymount-ussing-chamber-slider","image":"https://cdn.shopify.com/s/files/1/0653/7530/5944/products/P2408_Ussing_Chamber_Slider_Insert.jpg?v=1736970410","price":248,"priceMax":null,"currency":"USD","priceText":"$248","availability":"in stock","category":"EasyMount Ussing Chamber Sliders","brand":"Physiologic Instruments","description":"P2408 EasyMount Low Volume Ussing Chamber Slider for Extremely Small Tissues APETURE SIZE: 0.8MM | Area = 0.005 cm 2 The P2408 EasyMount Low Volume Ussing Chamber slider is a specialized tool designed specifically for the study of extremely","updatedAt":"2026-11-25T14:51:47.000Z"},{"name":"P2407S EasyMount Ussing Chamber Slider","url":"https://physiologicinstruments.com/products/p2407s-easymount-ussing-chamber-slider","image":"https://cdn.shopify.com/s/files/1/0653/7530/5944/products/P2407_Ussing_Chamber_Slider_Insert.jpg?v=1736970409","price":365,"priceMax":null,"currency":"USD","priceText":"$365","availability":"in stock","category":"EasyMount Ussing Chamber Sliders","brand":"Physiologic Instruments","description":"P2407S EasyMount Low Volume Ussing Chamber Slider for Intestinal Biopsies APETURE SIZE: 2.0MM | Area = 0.031 cm 2 | with Silver Electrodes The P2407S EasyMount Low Volume Ussing Chamber slider is a specialized tool designed for use with the","updatedAt":"2026-11-25T14:51:47.000Z"},{"name":"P2407C EasyMount Ussing Chamber Slider","url":"https://physiologicinstruments.com/products/p2407c-easymount-ussing-chamber-slider","image":"https://cdn.shopify.com/s/files/1/0653/7530/5944/products/P2407C_Ussing_Chamber_Slider_Insert.jpg?v=1736970408","price":248,"priceMax":null,"currency":"USD","priceText":"$248","availability":"in stock","category":"EasyMount Ussing Chamber Sliders","brand":"Physiologic Instruments","description":"P2407C EasyMount Low Volume Ussing Chamber Slider for Intestinal Biopsies APETURE SIZE: 1.5MM | Area = 0.18 cm 2 The P2407C EasyMount Low Volume Ussing Chamber slider is precisely engineered for use with the Low Volume EasyMount Ussing Cham","updatedAt":"2026-11-25T14:51:47.000Z"},{"name":"P2407B EasyMount Ussing Chamber Slider","url":"https://physiologicinstruments.com/products/p2407b-easymount-ussing-chamber-slider","image":"https://cdn.shopify.com/s/files/1/0653/7530/5944/products/P2407B_Ussing_Chamber_Slider_Insert.jpg?v=1736970407","price":248,"priceMax":null,"currency":"USD","priceText":"$248","availability":"in stock","category":"EasyMount Ussing Chamber Sliders","brand":"Physiologic Instruments","description":"P2407B EasyMount Low Volume Ussing Chamber Slider for Intestinal Biopsies APETURE SIZE: 1.2MM | Area = 0.11 cm 2 The P2407B EasyMount Low Volume Ussing Chamber Slider is a precision-designed accessory tailored for the Low Volume EasyMount U","updatedAt":"2026-11-25T14:51:47.000Z"},{"name":"P2407 EasyMount Ussing Chamber Slider","url":"https://physiologicinstruments.com/products/p2407-easymount-ussing-chamber-slider","image":"https://cdn.shopify.com/s/files/1/0653/7530/5944/products/P2407_Ussing_Chamber_Slider_Insert.jpg?v=1736970409","price":223,"priceMax":null,"currency":"USD","priceText":"$223","availability":"in stock","category":"EasyMount Ussing Chamber Sliders","brand":"Physiologic Instruments","description":"P2407 EasyMount Low Volume Ussing Chamber Slider for Intestinal Biopsies APETURE SIZE: 2.0MM | Area = 0.31 cm 2 The P2407 EasyMount Low Volume Ussing Chamber slider is a specialized tool designed for the Low Volume EasyMount Ussing Chamber","updatedAt":"2026-11-25T14:51:47.000Z"}],"productsUrl":"https://aifindme.com/api/v1/businesses/physiologic-instruments-inc/products"},"links":{"booking":null,"order":null,"menu":null,"pricing":null,"socials":[]},"images":{"logo":"https://physiologicinstruments.com/cdn/shop/files/physiologic-instruments-logo-blue_447x.png?v=1763753603","image":"http://physiologicinstruments.com/cdn/shop/files/pilogoaug22_9c0e8901-dd6a-40f7-8fa5-4bcb285bd4ce.png?v=1660952813"},"directory":{"url":"https://aifindme.com/b/physiologic-instruments-inc","markdown":"https://aifindme.com/b/physiologic-instruments-inc.md","json":"https://aifindme.com/b/physiologic-instruments-inc.json","llmsTxt":"https://aifindme.com/b/physiologic-instruments-inc/llms.txt","ownerVerified":false,"claimed":false,"verification":"unclaimed","lastChecked":"2026-11-25T14:51:47.733Z","lastChanged":"2026-11-25T14:51:47.733Z","listedSince":"2026-11-25T14:51:47.733Z","recheckedEveryDays":7,"status":"active","inactive":null,"completeness":{"have":6,"of":11,"missing":["Location or service area","Opening hours","Features","Social profiles","Booking, order, menu or pricing link"]},"sources":{"name":{"source":"structured data","url":"https://physiologicinstruments.com/"},"summary":{"source":"page metadata","url":"https://physiologicinstruments.com/"},"about":{"source":"page text","url":"https://physiologicinstruments.com/"},"email":{"source":"page text","url":"https://physiologicinstruments.com/"},"services":{"source":"page text","url":"https://physiologicinstruments.com/products/100-electrode-tips-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-s-electrode-set-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-vs-electrode-set-4-voltage-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-is-electrode-set-4-current-for-ussing-chamber-setups + https://physiologicinstruments.com/products/easymount-ussing-chamber-p2300"},"priceList":{"source":"structured data","url":"https://physiologicinstruments.com/ + https://physiologicinstruments.com/pages/contact + https://physiologicinstruments.com/blogs/news/how-ussing-chamber-systems-help-aquafeed-teams-optimize-nutrient-absorption + https://physiologicinstruments.com/pages/terms + https://physiologicinstruments.com/products/100-electrode-tips-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-s-electrode-set-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-vs-electrode-set-4-voltage-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-is-electrode-set-4-current-for-ussing-chamber-setups + https://physiologicinstruments.com/products/easymount-ussing-chamber-p2300"},"faqs":{"source":"page text","url":"https://physiologicinstruments.com/ + https://physiologicinstruments.com/pages/contact + https://physiologicinstruments.com/blogs/news/how-ussing-chamber-systems-help-aquafeed-teams-optimize-nutrient-absorption + https://physiologicinstruments.com/pages/terms + https://physiologicinstruments.com/products/100-electrode-tips-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-s-electrode-set-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-vs-electrode-set-4-voltage-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-is-electrode-set-4-current-for-ussing-chamber-setups + https://physiologicinstruments.com/products/easymount-ussing-chamber-p2300"},"paymentMethods":{"source":"page text","url":"https://physiologicinstruments.com/ + https://physiologicinstruments.com/pages/contact + https://physiologicinstruments.com/blogs/news/how-ussing-chamber-systems-help-aquafeed-teams-optimize-nutrient-absorption + https://physiologicinstruments.com/pages/terms + https://physiologicinstruments.com/products/100-electrode-tips-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-s-electrode-set-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-vs-electrode-set-4-voltage-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-is-electrode-set-4-current-for-ussing-chamber-setups + https://physiologicinstruments.com/products/easymount-ussing-chamber-p2300"},"languages":{"source":"page metadata","url":"https://physiologicinstruments.com/ + https://physiologicinstruments.com/pages/contact + https://physiologicinstruments.com/blogs/news/how-ussing-chamber-systems-help-aquafeed-teams-optimize-nutrient-absorption + https://physiologicinstruments.com/pages/terms + https://physiologicinstruments.com/products/100-electrode-tips-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-s-electrode-set-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-vs-electrode-set-4-voltage-for-ussing-chamber-setups + https://physiologicinstruments.com/products/p2020-is-electrode-set-4-current-for-ussing-chamber-setups + https://physiologicinstruments.com/products/easymount-ussing-chamber-p2300"},"foundingYear":{"source":"page text","url":"https://physiologicinstruments.com/"},"logo":{"source":"structured data","url":"https://physiologicinstruments.com/"},"image":{"source":"page metadata","url":"https://physiologicinstruments.com/"},"contactLink":{"source":"page text","url":"https://physiologicinstruments.com/"},"category":{"source":"page text","url":"https://physiologicinstruments.com/"},"webShop":{"source":"page metadata","url":"https://physiologicinstruments.com/"},"platform":{"source":"page metadata","url":"https://physiologicinstruments.com/"},"currency":{"source":"shop platform data","url":"https://physiologicinstruments.com/products.json"},"shopStatus":{"source":"shop platform data","url":"https://physiologicinstruments.com/products.json"},"productCount":{"source":"shop platform data","url":"https://physiologicinstruments.com/products.json"},"country":{"source":"shop platform data","url":"https://physiologicinstruments.com/meta.json"},"city":{"source":"shop platform data","url":"https://physiologicinstruments.com/meta.json"},"region":{"source":"shop platform data","url":"https://physiologicinstruments.com/meta.json"},"shippingCountries":{"source":"shop platform data","url":"https://physiologicinstruments.com/meta.json"},"productsUpdatedAt":{"source":"shop platform data","url":"https://physiologicinstruments.com/products.json"},"productPrices":{"source":"shop platform data","url":"https://physiologicinstruments.com/products.json"},"shopCategories":{"source":"shop platform data","url":"https://physiologicinstruments.com/products.json"}},"attributions":[]}}