# RH Designs

> Analyser Pro/500 Stopclock Timers ZoneMaster IIm Timer 3 ProcessMaster II PaperFlasher II SafeTorch Range Accessories Add Your Heading Text Here

- **Category:** Shops & Retail
- **Website:** https://rhdesigns.co.uk/
- **Country:** United Kingdom
- **Email:** sales@rhdesigns.co.uk
- **Founded:** 1994
- **Company number:** 12491283
- **Web shop:** Web shop on WooCommerce: 33 products, £1.95–£649
- **Shipping information:** https://rhdesigns.co.uk/delivery
- **Returns information:** https://rhdesigns.co.uk/warranty-returns/
- **Contact page:** https://rhdesigns.co.uk/contact-us/

## About
Thank you for visiting RH Designs’ darkroom equipment pages. This is the home of some of the most innovative and highly acclaimed darkroom equipment you can buy! Please browse around the site. If you have comments or questions about our products or services, or simply need more information and want to contact us, click on the contact or ordering information buttons on any page within this site. RH Designs has been operating for 25 years under the management of its owner, Richard Ross. Upon Richard’s retirement, Secondhand Darkroom Supplies ltd purchased the company and bought it under the umbrella of their general operations.

## What they sell
Sells: ACCESSORIES, ANALYSER PRO/500, STOPCLOCK TIMERS, SAFELIGHT TORCH, SAFELIGHTS, PAPER FLASHER II, PROCESS MASTER IIm, TIMER 3, ZONEMASTER IIm
Price range: £1.95–£649 (33 products, 12 shown here)

- Heiland TRD-2 Black and White Densitometer: £649 (in stock) — https://rhdesigns.co.uk/product/heiland-trd-2-black-and-white-densitometer/
- RH Designs standard footswitch: £26.90 (in stock) — https://rhdesigns.co.uk/product/rh-designs-standard-footswitch/
- ANAYLSER/ZONEMASTER METERING PROBE 2m EXTENSION CABLE: £6.90 (in stock) — https://rhdesigns.co.uk/product/anaylser-zonemaster-metering-probe-2m-extension-cable/
- PROCESS MASTER IIm PROBE DELUXE: £45 (in stock) — https://rhdesigns.co.uk/product/process-master-iim-probe-deluxe/
- IEC C14 Plug to 10A UK Socket Power Lead, 0.5m: £7.95 (in stock) — https://rhdesigns.co.uk/product/iec-c14-plug-to-10a-uk-socket-power-lead-0-5m/
- IEC C14 CEE 7/5 Power Cord, 200mm: £11.95 (in stock) — https://rhdesigns.co.uk/product/iec-c14-cee-7-5-power-cord-200mm/
- ANALYSER PRO REPLACEMENT GREYSCALE: £1.95 (in stock) — https://rhdesigns.co.uk/product/analyser-pro-replacement-greyscale/
- RH DESIGNS ANALYSER PRO 110V: £469 (in stock) — https://rhdesigns.co.uk/product/rh-designs-analyser-pro-110v/
- RH DESIGNS ANALYSER PRO 220V: £469 (in stock) — https://rhdesigns.co.uk/product/rh-designs-anaylser-pro-220v/
- RH DESIGNS TIMER 3: £229 (in stock) — https://rhdesigns.co.uk/product/rh-designs-timer-3/
- RH DESIGNS STOPCLOCK VARIO CABLE for Zone VI enlarger: £30 (in stock) — https://rhdesigns.co.uk/product/rh-designs-stopclock-vario-cable-for-zone-vi-enlarger/
- RH DESIGNS STOPCLOCK VARIO CABLE: £36 (in stock) — https://rhdesigns.co.uk/product/rh-designs-stopclock-vario-cable/

Products as published by the shop (read from the shop 2026-11-23; the shop last changed its products 2026-08-31; last change seen here 2026-11-23); prices and stock change.

## Prices
- sales@rhdesigns.co.uk: £0.00
- Basic post (non-trackable): £10.00
- ORDER OVER: £50.00
- EUROPE-EU: £15.00
- USA/CANADA: £30.00
- REST OF THE WORLD: £60.00

## Frequently asked questions

**I can’t decide between a StopClock Professional and an Analyser Pro. Can you help?**
What are the relative merits of the Analyser Pro vs the Heiland SplitGrade System? The difference is best likened to that between an automatic-exposure camera and a hand-held spotmeter. The SplitGrade system is highly automated and as such can deliver good quality prints from most negatives, but it can be caught out by for example a picture of a fried egg on a white plate – much like the auto-exposure camera it will deliver 90% of the time but you need to be aware of its limitations. It does of course have full manual override for such circumstances. The Analyser Pro is, like a spotmeter, more

**What are the relative merits of the Analyser Pro vs the Heiland SplitGrade System?**
What’s involved in calibration of the Analyser Pro / ZoneMaster? Basically, you need to make test strips at the white end to establish any exposure compensation, then make test strips at the black end to adjust the contrast. The products incorporate a test strip mode which generates the necessary time sequences automatically. The new Calibration Kit makes the process much easier than previously.

**What’s involved in calibration of the Analyser Pro / ZoneMaster?**
Is the timer section of the Analyser Pro the same as the StopClock Professional? No. It is essentially identical to the now discontinued StopClock LE. It has one channel and does not have the programmable exposure sequences. It also does not have the Dry-Down feature but this is not necessary as the exposure is determined based on the final dry print tones indicated on the grey scale.

**Is the timer section of the Analyser Pro the same as the StopClock Professional?**
What features of the StopClock Professional are missing from the Analyser Pro’s timer? Basically, the second channel, the programmable exposure sequences and the dry-down compensation.

**What features of the StopClock Professional are missing from the Analyser Pro’s timer?**
What timing benefits would I get from the StopClock Professional over the Analyser Pro? Flexibility, programmability, precision. The StopClock Professional offers programmed sequences of exposures so that once you’ve decided on the exposures needed for a print they can all be entered into the timer’s memory. You can then concentrate on the image. In particular, multiple copies of complex prints are very easy to make as the timer retains the entire sequence in its memory. Split grade printing is easier owing to the second timing channel and dedicated split grade mode. And the higher resolution

**What timing benefits would I get from the StopClock Professional over the Analyser Pro?**
Are your timers suitable for cold cathode (cold light) heads? Yes. All our enlarger timer products use heavy-duty relays with 10A contact rating, and surge ratings in excess of 80A. In addition, the StopClock Vario can compensate for the light level fluctuations typical of such heads.

**Are your timers suitable for cold cathode (cold light) heads?**
Is the ZoneMaster’s metering system the same as the Analyser Pro’s? Yes, they’re identical.

**Is the ZoneMaster’s metering system the same as the Analyser Pro’s?**
My enlarger has an Ilford Multigrade head. Can I use an Analyser or StopClock Professional with it? You cannot use the standard version of these products – the Ilford head does not have provision for an external timer. You can choose an Analyser 500 or StopClock 500, either of which will replace the Ilford control pad. If you want to keep the Ilford control pad you can use a ZoneMaster II and transfer the grade and time readings to it.

**My enlarger has an Ilford Multigrade head. Can I use an Analyser or StopClock Professional with it?**
My Durst/Kaiser/Other enlarger’s lamp seems to take half a second or so to come on. Will this cause inaccuracies? This delay is inherent in some stabilised transformers and normally makes it very difficult to match a final print to a test strip. All our timers can compensate for this so that for example two 5 second exposures will produce the same density as a single 10 second exposure.

**My Durst/Kaiser/Other enlarger’s lamp seems to take half a second or so to come on. Will this cause inaccuracies?**
What are the differences between the StopClock Professional and the Vario version? The Vario loses the ability to connect to a ZoneMaster but will compensate for enlarger light output variations. They are otherwise identical.

**What are the differences between the StopClock Professional and the Vario version?**
Why can’t a StopClock Vario connect to a ZoneMaster II? The Vario reads the lamp output and adjusts the exposure time to compensate for variations, so for example if the lamp output falls the exposure time is increased. The ZoneMaster, like any exposure meter, also reads the lamp output and if it falls, the meter will suggest a longer exposure time (all other things being equal). Consequently, the combination of the ZoneMaster and Vario will over-compensate for lamp variations. The ZoneMaster relies on a constant lamp output in order to determine the density variations in the negative correctl

**Why can’t a StopClock Vario connect to a ZoneMaster II?**
I have a cold light head and a halogen head. Can the Vario be used on the halogen head without the light sensor? Yes. It will automatically switch to normal timing mode if the sensor is disconnected.

**I have a cold light head and a halogen head. Can the Vario be used on the halogen head without the light sensor?**
How do I connect my enlarger to the timer? We supply the necessary connectors which conform to the emerging industry standard CEE22 format. You may have seen these plugs on electric kettles, person

**How do I connect my enlarger to the timer?**
<img fetchpriority="high" decoding="async" class="size-medium wp-image-343 alignright" src="http://rhdesigns.myfreestart.co.uk/wp-content/uploads/2020/04/AnalyserRear-300x207.jpg" alt="" width="300" height="207" srcset="https://rhdesigns.co.uk/wp-content/uploads/2020/04/AnalyserRear-300x207.jpg 300w, https://rhdesigns.co.uk/wp-content/uploads/2020/04/AnalyserRear-64x44.jpg 64w, https://rhdesigns.co.uk/wp-content/uploads/2020/04/AnalyserRear.jpg 350w" sizes="(max-width: 300px) 100vw, 300px" />al computers etc. You can see them in this picture. The timer is a mains switch, so you must retain any

**I have a DeVere enlarger with a Transtab power supply. How do I connect this to the timer?**
I have a sodium-type safelight (e.g. Thomas Duplex or Kaiser Duka 50). Can I use this with the Analyser / ZoneMaster? No – these safelights cannot be switched off and then on again quickly; the lamp does not re-strike properly. If you have a safelight of this type you will need either to switch it off permanently (and use a conventional safelight) or arrange some type of mechanical shutter to shut off its light during measurements. All exposure meters will be affected by safe lighting, even those which claim immunity, so for best results the safelight must be switched off during measurements.

**My portrait (or other image) has too much contrast, what am I doing wrong?**
I think I’ve messed up the calibration in my meter. How do I restore the factory settings? Simply press ‘Clear’ while in calibration mode. Exposure compensation and contrast modes and each of the eight paper channels are cleared separately. For example, if you want to clear PAP4, first select PAP4 using short presses of the Cal button. Now press and hold Cal until “CAL” appears on the display. Press Clear, then Focus, then Clear again, then Focus again. PAP4 is now reset to factory calibration (=Ilford MG4 / filters).

**I think I’ve messed up the calibration in my meter. How do I restore the factory settings?**
I’m using a chromogenic film (e.g. Ilford XP2, Kodak T400CN). How will this affect the meter? These films can have enough colouration in the base and image to affect the contrast on variable contrast papers. You may need to print at 0.5 to 1.0 grade higher contrast than the meter’s suggestion with Ilford and 1.0 to 1.5 grades with Kodak. Since these negatives do not scatter light in the same way as silver based emulsions, the transmission density reading taken by projection will be less contrasty than a conventional transmission density reading. In addition with Kodak’s T400CN, the orange base

**I’m using a chromogenic film (e.g. Ilford XP2, Kodak T400CN). How will this affect the meter?**
I develop my negatives in a staining developer (e.g. Pyro). Will this have an effect? We’ve found that, perhaps surprisingly, the stain doesn’t affect variable contrast papers very much. Its effects tend to be more pronounced on fixed grade papers. However, because of the nature of the stain it’s often inconsistent so the best advice we can offer is to “try it and see”!

**I develop my negatives in a staining developer (e.g. Pyro). Will this have an effect?**
What about Cold Light (Cold Cathode) Enlargers? Because of the high blue-green light efficiency of these units, exposure times can be about 1-3 stops shorter than predicted. This high sensitivity catches some users out, since the normal test strip calibration method will be a long way off the correct setting unless some compensation is added. Start with one or two stops of negative exposure compensation as a coarse adjustment which can then be refined by the usual calibration methods.

## Features
- Delivery

## Languages
- English

---
Source: AI Find Me directory (https://aifindme.com/b/rh-designs). Facts were read from https://rhdesigns.co.uk/ and last checked 2026-11-23; every listing is re-checked about every 7 days. Unclaimed listing. Not yet verified by the business owner.
JSON version: https://aifindme.com/b/rh-designs.json (it says where each fact comes from)
