# Thermoscreens

> Thermoscreens are industry leaders in the production and distribution of ambient, electric & water heated air curtains. Learn more.

- **Category:** Shops & Retail
- **Website:** https://thermoscreens.com/
- **Address:** St Mary’s Road, Nuneaton, Warwickshire, CV11 5AU
- **Country:** United Kingdom
- **Phone:** +44 (0) 24 7638 4646
- **Email:** sales@thermoscreens.com
- **Web shop:** Web shop on WooCommerce: 168 products, £1,967–£7,298
- **Returns information:** http://returns.thermoscreens.com/
- **Book:** https://thermoscreens.com/book-site-survey/
- **Contact page:** https://thermoscreens.com/contact-us/

## About
Thermoscreens were one of the pioneers of modern air curtain technology, and we remain at the forefront of its evolution today. Our sales team work hand-in-hand with an international network of distributors, providing solutions to customers of all types and sizes, in more than 50 countries. Our name is synonymous with the highest quality standards; our products renowned for their energy efficiency, reliability and ease of use. As a leading provider of indoor climate solutions, our HVAC products and systems, understanding of environments and expert service make us the trusted provider for guaranteed comfort and quality. To be the indoor environment experts. We have many years’ experience.

## What they sell
Sells: Surface Mounted, Recessed
Price range: £1,967–£7,298 (168 products, 12 shown here)

- PHV3000A V: £5,920 (in stock) — https://thermoscreens.com/phv3000a-v/
- PHV2500A V: £5,118 (in stock) — https://thermoscreens.com/phv2500a-v/
- PHV2000A V: £4,269 (in stock) — https://thermoscreens.com/phv2000a-v/
- PHV1500A V: £3,612 (in stock) — https://thermoscreens.com/phv1500a-v/
- PHV1000A V: £2,931 (in stock) — https://thermoscreens.com/phv1000a-v/
- PHV3000E V: £7,298 (in stock) — https://thermoscreens.com/phv3000e-v/
- PHV2500E V: £6,451 (in stock) — https://thermoscreens.com/phv2500e-v/
- PHV2000E V: £5,652 (in stock) — https://thermoscreens.com/phv2000e-v/
- PHV1500E V: £4,856 (in stock) — https://thermoscreens.com/phv1500e-v/
- PHV1000E V: £3,994 (in stock) — https://thermoscreens.com/phv1000e-v/
- HX2000AR: £3,897 (in stock) — https://thermoscreens.com/hx2000ar/
- HX1500AR: £3,190 (in stock) — https://thermoscreens.com/hx1500ar/

Products as published by the shop (read from the shop 2026-11-28; the shop last changed its products 2026-11-12; last change seen here 2026-11-28); prices and stock change.

## Frequently asked questions

**Why has the Thermal Cut Out (TCO) tripped on electric heated units?**
The most common reasons for the TCO (or both TCO’s in the case of 2m units) tripping are incorrect installation, insufficient maintenance, or inappropriate heat and fan settings. Incorrect installation Make sure surface mounted units are not fitted in the ceiling void. Check the gap above the air curtain. For surface mounted units this should be at least 100mm. Make sure the discharge air stream is not being deflected back into the cabinet by the top edge of the doorway or any other doorway obstruction. Insufficient maintenance Check air ventilation holes and inlet/outlet grilles are not…

**How do I find the TCO?**
On surface mounted and recessed units, the TCO is labelled ‘Press to reset’. On Designer units, it is marked with a red circle. Surface mounted units On C and PHV units the TCO is located on the top of the outer case. On T Units it is inside the fan deck, and the grille needs to be removed to access it. Recessed units On all recessed air curtains, the TCO is located inside the unit above the electric elements. The grille core will need to be removed in order to access the TCO. Designer units On Designer units, the TCO is around ten holes in from the left and three rows in from the back and is…

**How will I know that the TCO has tripped?**
Air curtains manufactured from 2015 onwards: The LEDs on the Touch remote control will flash on and off. Air curtains manufactured before 2015: The status LED on the Touch PCB inside the air curtain will be continuous red. (You will need to access to the air curtain to check this).

**What do I need to check before I reset the TCO?**
Before resetting ensure there is adequate air flow from the air curtain, and that the unit has been commissioned as per the installation, operation and maintenance instructions.

**How do I reset the TCO?**
Air curtains manufactured from 2015 onwards: Click here to view our how-to guide on how to reset your overheated Air Curtain: How to reset your air curtain Switch off the electrical supply to the air curtain and allow 10 minutes for it to cool down. Then turn the power back on and press the Auto Reset button on the Touch remote control four times. Air curtains manufactured before 2015: Switch off the electrical supply to the air curtain and allow 10 minutes for it to cool down. Access the TCO inside the unit and press the red button until it clicks in (There are two TCOs on 2m units or longer…

**How will I know the reset has been successful?**
Air curtains manufactured from 2015 onwards: The air curtain heaters will come back on and, after 30 seconds, the LEDs on the remote control will stop flashing. Air curtains manufactured before 2015: The air curtain heaters will come back on and the status LED on the Touch PCB inside the air curtain will change from continuous red to flashing green.

**Where are the internal fuses located?**
The internal fuses are located on the Touch PCB and inside the air curtain: Fuse 6.3A(T) supplies the fan motors within the air curtain Fuse 100mA(F) controls the circuitry of the Touch PCB

**Are joining kits available for all horizontally mounted units?**
Joining kits are available for C, T, HP, HX, and PHV surface mounted air curtains. For more information call our Sales Office on 02476 384 646

**What should I do if the heating elements are not getting hot?**
Check all wires are correctly connected to the control panel, elements and wall controller. For electric models ensure the correct supply is present and appropriately connected. Most electrical heated models require a 3-phase 400v electrical supply, they will not heat with a 1-phase 230v supply. The Thermal Cut Out (TCO) may have tripped and overheated

**What is the typical casing temperature under normal operating conditions?**
Under normal operating conditions the casing temperature should be between 60-80°C. A thermal protection device is embedded in the winding of each motor to prevent overheating.

**Why is the motor running hot?**
The most likely cause of the motor running hot is a build-up of dust or dirt deposits on the fan impellers. This can cause vibration, noise and excessive wear on the motor bearings.

**How do I reduce the risk of overheating?**
Regular cleaning will minimise the risk of overheating, optimise the efficiency of your air curtain, and prolong its operating life. We recommend that units are cleaned at least once every three months.

**Can electric units be factory downrated to single phase?**
Some electric units can be downrated in the factory before the units are despatched at no extra cost. Contact Thermoscreens sales office for more information. Please note that 1 phase units may well not provide enough heat output for a normal air curtain installation.

**Can I downrate electric units myself?**
No. We do not recommend downrating units on site. Any conversion needs to be carried out at the factory at the time of order, or by a recognised Thermoscreens technician. Converting a unit yourself will invalidate your warranty.

**How can I tell the difference between a single phase and a three phase unit?**
Single phase units have a bridge on the terminal block, which connects L1, L2, L3 together. With three phase units, there is no bridge.

## Payment methods
- iDEAL
- Cash

## Languages
- English
- German
- Dutch
- Polish
- French

## Social profiles
- Facebook: https://www.facebook.com/Thermoscreens-118520259550697/
- LinkedIn: http://www.linkedin.com/company/thermoscreens

---
Source: AI Find Me directory (https://aifindme.com/b/thermoscreens). Facts were read from https://thermoscreens.com/ and last read 2026-11-28; listings are re-checked regularly. Unclaimed listing. Not yet verified by the business owner.
Fields with a value: 9 of 11. No field was entered by the owner.
JSON version: https://aifindme.com/b/thermoscreens.json (it says where each fact comes from)