# Vacumetrics

> Vacumetrics, based just south of Boston, MA, is a trusted partner for helium leak detector sales, repairs, and maintenance, proudly serving the aerospace, defense, communications, science, and automotive industries across the Northeast.

- **Category:** Shops & Retail
- **Website:** https://vacumetrics.com/
- **Address:** 103 Old Colony Avenue Unit 2-R, 02718 East Taunton, MA, United States
- **Country:** United States
- **Phone:** +1-508-821-9420
- **Email:** info@vacumetrics.com
- **Founded:** 2003
- **Web shop:** Web shop on Shopify: 97 products, $5.95–$5,037
- **Ships to:** United States, United Kingdom
- **Contact page:** https://vacumetrics.com/pages/contact-us
- **Map:** https://www.openstreetmap.org/?mlat=41.88599412999159&mlon=-71.02707304476412#map=17/41.88599412999159/-71.02707304476412

## About
Vacumetrics, based just south of Boston, MA, is your trusted partner for helium leak detector sales, repairs, and maintenance, proudly serving the aerospace, defense, communications, science, and automotive industries across the Northeast. We have extensive experience servicing all makes and models of helium leak detectors, allowing you the convenience of working with a single, reliable vendor for all your systems, no matter the brand. Our team brings extensive experience from every facet of the helium leak detector industry - from manufacturing and service to end-user applications.

## What they sell
Sells: Best Selling Products, Newest Products, Leak Detector Parts, Vacuum Hardware, Vacuum Pumps, Spare Parts and Kits - System Components, Varian 947, Compatible Parts - adixen by Pfeiffer Vacuum ASM142, Compatible Parts - adixen by Pfeiffer Vacuum ASM182, Compatible Parts - adixen by Pfeiffer Vacuum ASM192, Varian 936-70, Compatible Parts - Leybold Phoenix, Compatible Parts - Leybold Phoenix 4.0, LACO TitanTest, Varian 938-41, Varian 979, Compatible Parts - Pfeiffer Qualytest HLT260/275, Compatible Parts - Pfeiffer Smart Test 550/560/570, Helium Leak Detectors, Spare Parts and Kits - Electronics, Varian 956, Compatible Parts - adixen by Pfeiffer Vacuum ASM310, Compatible Parts - INFICON UL5000, Our Best Selling Parts, Pump Parts, Oil and Accessories, Spare Parts and Kits - Filters, Varian 959, Compatible Parts - adixen by Pfeiffer Vacuum ASM340, Compatible Parts - adixen by Pfeiffer Vacuum ASM380, Compatible Parts - INFICON UL1000
Price range: $5.95–$5,037 (97 products, 12 shown here)

- KF-50 Centering Ring w/ O-Ring (304 Stainless): $13.65 (in stock) — https://vacumetrics.com/products/kf-50-centering-ring-w-o-ring-304-stainless
- KF-40 Centering Ring w/ O-Ring (304 Stainless): $10.50 (in stock) — https://vacumetrics.com/products/kf-40-centering-ring-w-o-ring-304-stainless
- KF-16 Centering Ring w/ O-Ring (304 Stainless): $5.95 (in stock) — https://vacumetrics.com/products/kf-16-centering-ring-w-o-ring-304-stainless
- KF-25 Centering Ring w/ O-Ring (304 Stainless): $5.99 (in stock) — https://vacumetrics.com/products/kf-25-centering-ring-w-o-ring-304-stainless
- Leybold RC310WL Wireless Remote Control for Leak Detectors: $4,029 (in stock) — https://vacumetrics.com/products/leybold-rc310wl-wireless-remote-control-for-leak-detectors
- Leybold Valve Rebuild Kit: $192 (in stock) — https://vacumetrics.com/products/200001369
- KF40 Centering Ring w/ O Ring (304 Stainless): $5.99 (in stock) — https://vacumetrics.com/products/kf40-centering-ring-w-o-ring-304-stainless
- KF25 Centering Ring w/ O Ring (304 Stainless): $5.99 (in stock) — https://vacumetrics.com/products/kf25-centering-ring-w-o-ring-304-stainless
- KF16 Centering Ring w/ O Ring (304 Stainless): $5.99 (in stock) — https://vacumetrics.com/products/kf16-centering-ring-w-o-ring-304-stainless
- KF25 Bellows - Braided 500mm (19.68"): $198 (in stock) — https://vacumetrics.com/products/kf25-bellows-braided-500mm-19-68
- KF25 Bellows - 1000mm (39.37"): $185 (in stock) — https://vacumetrics.com/products/kf25-bellows-1000mm-39-37
- KF25 Bellows - 750mm (29.52"): $134.40 (in stock) — https://vacumetrics.com/products/kf25-bellows-750mm-29-52

Products as published by the shop (read from the shop 2026-11-17; the shop last changed its products 2026-11-17; last change seen here 2026-11-17); prices and stock change.

## Services
- Equipment Sales
- Service & Repair
- Products
- Helium Leak Detectors
- Vacuum Pumps and Accessories
- Spare Parts and Kits
- Leak Detection Cart Systems

## Prices
- SMART-Spray - Helium Spray Gun: $0.00
- Leybold PHOENIX Quadro Dry Plus: $0.00
- Leybold PHOENIX Quadro: $0.00
- Leybold PHOENIX Vario: $0.00

## Frequently asked questions

**What's the difference between a wet and dry helium leak detector?**
Wet leak detectors use an oil sealed pump in their vacuum system, which offers strong sensitivity but requires more maintenance and can contaminate sensitive processes. Dry leak detectors use oil free pumps instead, making them better suited for clean environments like semiconductor fabs, though they historically had a harder time recovering from helium contamination. Newer dry models, like Leybold's PHOENIX Quadro Dry Plus, have closed much of that performance gap.

**How do I choose a helium leak detector for semiconductor manufacturing vs automotive production?**
Semiconductor applications typically call for a dry, oil free detector to avoid contaminating an ultra clean vacuum environment, along with high sensitivity for detecting extremely small leaks. Automotive production usually prioritizes speed and throughput for testing components like fuel systems and AC parts on a production line, so a durable, fast cycling detector matters more than ultra high sensitivity. Talking through your specific tolerances and environment with a Vacumetrics specialist is the fastest way to land on the right model.

**What detection sensitivity do I need for my application?**
Sensitivity requirements depend on the component's function and the consequences of a leak, expressed as a leak rate in mbar·L/s. Aerospace, semiconductor, and hermetically sealed electronic components often require detection down to the 10⁻¹² mbar·L/s range, while less critical industrial applications can work with less sensitive equipment. Your quality standards, industry regulations, or customer specifications usually dictate the number you need to hit.

**What's the difference between vacuum leak testing and sniffer leak testing?**
Vacuum leak testing pressurizes or evacuates a sealed part and measures helium passing through the detector's own vacuum system, which is generally the more sensitive method. Sniffer leak testing uses a handheld probe to sample ambient air near a part that's been filled with helium, which is faster and more flexible for large or hard to evacuate assemblies but less sensitive overall. Many facilities use both methods depending on the part and the stage of production.

**What's a leak detection cart system and do I need one?**
A leak detection cart is a mobile, self-contained setup that houses a leak detector along with supporting components like pumps, gauges, and accessories for easy movement around a facility. It's an inexpensive solution that gives you the flexibility to test in multiple locations on a production floor, or in tight spaces where a fixed installation isn't practical. Standard cart configurations are available from Vacumetrics to suit most needs, and custom carts can be built for specific facility requirements.

**Should I buy new or certified/refurbished leak detection equipment?**
New equipment comes with full manufacturer warranties, typically two to three years, and the latest technology, which matters most in high stakes or regulated environments. Given the long life expectancy of a modern leak detector, the annual cost of a new machine is quite reasonable. Certified or refurbished units can offer solid performance at a lower cost for facilities with less demanding requirements, as long as they've been properly serviced and calibrated. A Vacumetrics specialist can help you weigh the tradeoff based on your application and budget.

**How does helium leak detection work?**
A part is either filled with helium and monitored from the outside, or placed under vacuum while helium is sprayed around it from the outside. The leak detector's mass spectrometer draws in gas from the test setup and identifies the presence of helium atoms that have passed through any leak path. The size of the detected helium signal corresponds to the size of the leak, which the detector reports as a leak rate.

**Why is helium used for leak testing instead of other gases?**
Helium is a small, light, inert molecule, which lets it pass through even microscopic leak paths that larger gas molecules can't. It's also naturally rare in the atmosphere, at roughly 5 parts per million, so background interference is minimal and any helium detected is likely coming from the test part. On top of that, it's non-toxic, non-flammable, and inexpensive relative to other trace gases used in leak testing.

**What is background suppression (I-ZERO) in leak detection?**
Background suppression is a function that filters out residual helium that has accumulated in a leak detector's system from repeated testing, so it doesn't get mistaken for a leak signal from the current test. INFICON's I-ZERO is one implementation of this, allowing continuous leak testing at background levels significantly lower than would otherwise be possible. This is especially useful in high volume testing environments where helium can build up quickly.

**What leak rate is considered acceptable for hermetically sealed components?**
Acceptable leak rates vary widely by industry and application, but many hermetically sealed electronic and aerospace components are tested against standards like MIL-STD-883 Method 1014, which defines specific leak rate thresholds based on package size. Medical devices and other critical components often have their own regulatory or customer driven leak rate specifications. There isn't a single universal number, so the right threshold depends on the standard or specification governing your part.

**How does a mass spectrometer detect leaks?**
The mass spectrometer inside a leak detector ionizes the gas sample it draws in, then uses a magnetic field to separate ions by their mass to charge ratio. Because helium has a distinct, light mass, the instrument can isolate and measure helium ions separately from all the other gases present in the sample. The resulting ion current is converted into a leak rate reading that the technician can interpret.

**How often should a helium leak detector be calibrated?**
Most facilities calibrate the internal leak in their leak detectors on a schedule ranging from six to twelve months, although an annual calibration and service is most common. At the beginning of each day or shift the leak detector uses the internal calibrated leak to check system functionality and calibration. Depending on the criticality of the parts being tested, and any regulatory or customer requirements, other calibration cycles might be required. Equipment used in high volume or high stakes environments, like aerospace or medical device manufacturing, often needs more frequent calibrati

**What does NIST-certified calibration mean and why does it matter?**
NIST-certified calibration means a leak detector's measurements have been verified against reference standards that trace back to the National Institute of Standards and Technology, confirming the equipment reads leak rates accurately. This traceability is often a requirement for quality systems like ISO 9001 and for industries such as aerospace, defense, and medical devices. Without it, you have no independent assurance that your equipment's readings are trustworthy.

**How long does a typical repair or calibration turnaround take?**
Turnaround time depends on the issue, the part availability, and whether the equipment needs to be shipped in or can be serviced on-site. Annual preventative maintenance and calibrations take less than a full day and can be scheduled at your convenience. Complicated repairs involving replacement of electronics or the rebuilding of turbo molecular pumps may take a week or more. Vacumetrics stocks typical wear parts such as ion sources and valve rebuild kits for quick turnaround.

**Do you service leak detectors you didn't sell us?**
Yes, Vacumetrics services all makes and models, not only of helium leak detectors but also any make and model of associated vacuum pumps. Our history of servicing entire helium leak detector fleets lets you work with a single vendor for new systems, maintenance, repairs, and parts with a single point of contact. We also keep your equipment in our database so we can track your systems' service history and make proactive suggestions for service.

## Languages
- English

## Service area
- Northeastern United States

## Social profiles
- LinkedIn: https://www.linkedin.com/company/vacumetrics/

---
Source: AI Find Me directory (https://aifindme.com/b/vacumetrics). Facts were read from https://vacumetrics.com/ and last checked 2026-11-17; every listing is re-checked about every 7 days. Unclaimed listing. Not yet verified by the business owner.
JSON version: https://aifindme.com/b/vacumetrics.json (it says where each fact comes from)
