Resistance Thermometer Theory And Practice

WebsiteCallMenuContact

The facts

Country
United Kingdom
Opening hours
Closed now · opens Mon 08:00All opening hours
Phone
00441243871280
Email
sales@labfacility.com
Founded
1971
Payment
PayPal, Apple Pay, Google Pay, Klarna, iDEAL
Languages
English
Shipping information
Shipping page
Returns
within 30 days Returns page
Social
LinkedIn · YouTube · Facebook · X · Instagram

What they sell

Web shop on Magento

Facts as published by the shop

Facts as published by the shop. Prices and stock change; the shop’s website has the current ones.

Opening hours

Closed now · opens Mon 08:00

Mon–Thu08:00–17:00
Fri08:00–12:30
Sat, SunClosed

Times in the business’s local time (Europe/London).

About

Labfacility are the UK's leading manufacturer of Temperature Sensors, Thermocouple Connectors and associated Temperature Instrumentation and stockists of Thermocouple Cables. The Company has been trading since 1971 and is ISO 9001 accredited. We have two UK sites – West Sussex and South Yorkshire and export to over 85 countries, Shipments are made to world-wide destinations on a daily basis. In addition to the stocked items, Labfacility also offers bespoke Temperature Sensors. We are specialists in the design and manufacture of custom-built temperature sensors at our 18,000 square foot Yorkshire plant located in Dinnington.

Prices

Zone 1£12
Zone 2£59
Zone 3£73
Zone 4£88
Zone 5£89
Zone 6£113

Prices as shown on the website when it was last read; the business may have changed them since.

Frequently asked questions

1. What is the difference between a Mineral Insulated (MI) and a fabricated sheath?

2. How accurately can I measure temperature using a standard sensor?To published, internationally specified tolerances as standard, typically ± 2.5°C for popular thermocouples, ±0.5°C for PRT. Higher accuracy sensors can be supplied to order, e.g. ±0.5°C for type T thermocouple, ±0.2°C for PRT. All of these values are temperature dependent. A close tolerance, 4-wire PRT will give best absolute accuracy and stability.

2. How accurately can I measure temperature using a standard sensor?

3. How do I choose between a thermocouple and a PRT?Mainly on the basis of required accuracy, probe dimensions, speed of response and the process temperature.

3. How do I choose between a thermocouple and a PRT?

4. My thermocouple is sited a long way from my controller, is this a problem?It could be; try to ensure a maximum sensor loop resistance of 100 Ohms for thermocouples and 4-wire PRTs. Exceeding 100 Ohms could result in a measurement error. Note By using a 4-20mA transmitter near the sensor, cable runs can be much longer and need only cheaper copper wire. The instrument must be suitable for a 4-20mA input though.

4. My thermocouple is sited a long way from my controller, is this a problem?

5. What is the difference between a RTD and PRT sensor?Nothing. RTD means resistance thermometer detector (the sensing element) and PRT means Platinum resistance thermometer (the whole assembly) i.e. a PRT uses a RTD!

5. What is the difference between a RTD and PRT sensor?

6. What is a Pt100?An industry standard Platinum RTD with a value of 100 Ohms @0°C to IEC751; this is used in the vast majority of PRT assemblies in most countries.

6. What is a Pt100?

7. Should I choose a Type K or Type N thermocouple?Generally, Type N is more stable and usually lasts longer than Type K; N is a better choice for high temperature work depending on the choice of sheath material.

7. Should I choose a Type K or Type N thermocouple?

8. Does it matter what type of steel I specify for the thermocouple sheath?Often no, sometimes yes. In some cases, reliability depends on the ideal choice of material.

8. Does it matter what type of steel I specify for the thermocouple sheath?

9. Are there other types of temperature sensor apart from thermocouple and PRT Types?Several, but these two groups are the most common. Alternatives include thermistors, infra-red (non-contact), conventional thermometers (stem & dial types) and many others.

9. Are there other types of temperature sensor apart from thermocouple and PRT Types?

10. Why are so many different types of thermocouple used?They have been developed over many years to suit different applications world-wide.

10. Why are so many different types of thermocouple used?

11. What is a duplex sensor?One with two separate sensors in a single housing

11. What is a duplex sensor?

12. Why use a thermowell?To protect the sensor from the process medium and to facilitate its replacement if necessary.

12. Why use a thermowell?

13. I use many thermocouples in testing and experiments, can I make my own thermocouple junctions?Yes, using a benchtop welder and fine thermocouple wires – it is easy and inexpensive to make unsheathed thermocouples.

13. I use many thermocouples in testing and experiments, can I make my own thermocouple junctions?

14. Why should I use actual thermocouple connectors instead of ordinary electrical connectors?Good quality thermocouple connectors use thermocouple alloys, polarized connections and colour coded bodies to guarantee perfect, error-free interconnections.

14. Why should I use actual thermocouple connectors instead of ordinary electrical connectors?

15. Why offer 2,3 or 4 wire PRT probes?Because all 3 are encountered. Two-wire should be avoided, three-wire is widely used and four-wire gives optimum accuracy. Your instrument will be configured for 2,3 or 4 wire.

15. Why offer 2,3 or 4 wire PRT probes?

16. For thermocouple cable and connectors, why are there two colours available for the same calibration?Since December 1998, the International colour code to IEC 60584-3 should be observed.

Features

Wi-FiDelivery

Read from labfacility.com. Last read 3 h ago. 10 of 11 key facts have a value; missing: location or service area. Where these facts come from

Is this your shop?

This page was made automatically from labfacility.com, and nobody has verified it yet. Claiming is free and needs no approval. Facts you confirm replace what we read and are labelled “business owner”.

Claim this listing

What claiming means

Where these facts come from

Read from labfacility.com. Last read 3 h ago; last changed 3 h ago. Every listing is re-checked regularly. Nobody has claimed this listing yet, so no fact has been confirmed by the business itself.

Fields with a value: 10 of 11; a value was not checked by us. No field was entered by the owner. Known problems: none found by our automatic checks, which find some and not all.

The source of each fact

FactFound inPage
Namepage metadata/
Summarypage metadata/resistance-thermometer-theory-and-practice
Aboutpage text/
Phonepage text/
Emailpage text/
Opening hourspage text/contact
Opening hours (structured)page text/contact
Pricespage text/postage-delivery
FAQspage text/faq
Featurespage text/, /contact, /labfacility, /resistance-thermometer-theory-and-practice, /thermocouple-theory-and-practice, /faq, /postage-delivery
Payment methodspage text/, /contact, /labfacility, /resistance-thermometer-theory-and-practice, /thermocouple-theory-and-practice, /terms-conditions, /returns-policy, /faq, /postage-delivery
Languagespage metadata/, /contact, /labfacility, /resistance-thermometer-theory-and-practice, /thermocouple-theory-and-practice, /terms-conditions, /returns-policy, /faq, /postage-delivery
Foundedpage text/
Social profilespage text/, /contact, /labfacility, /resistance-thermometer-theory-and-practice, /thermocouple-theory-and-practice, /terms-conditions, /returns-policy, /faq, /postage-delivery
Menu linkpage text/
Contact pagepage text/
Return periodpage text/returns-policy
Shipping informationpage text/
Returns informationpage text/
Categorypage text/
Web shoppage metadata/
Shop platformpage metadata/
Countrywebsite signalslabfacility.com/

Recent checks

For AI assistants and developers

schema.org data is embedded in this page. Facts last read 28 November 2026.

How often this listing is read

Since 25 November 2026:

The page and its machine copies count. Most AI crawlers copy pages that may train a model or fill a search index: such a read is not a person, a visitor or a recommendation. How we count

More in Shops & Retail

Report this listing · Remove this listing