LabJack in Free Software Foundation: products, shipping and shop facts
Shops & Retail in Free Software Foundation · Web shop on Shopify · Unclaimed · Not verified by owner · facts last checked 22 November 2026 · read from labjack.com.
Facts
| Name | LabJack |
|---|---|
| Category | Shops & Retail |
| Summary | Superior Data Acquisition Systems to collect analog & digital sensors. Log, automate and test. Use software like LabVIEW, MatLAB, Python, C, C++, DAQFactory |
| Website | labjack.com |
| Address | Lakewood, CO 80235 USA |
| City | Free Software Foundation |
| Region | Colorado |
| Country | United States |
| Map location | 39.6500477, -105.0750092 · Map |
| Phone | (303) 942-0228 |
| support@labjack.com | |
| Contact page | https://labjack.com/pages/contact |
| Pricing page | https://labjack.com/u12/datarates |
| Founded | 2001 |
| Payment methods | iDEAL |
| Languages | English |
| Web shop | Web shop on Shopify: 36 products, $6–$1,400 |
| Currency | USD |
| What they sell | All LabJack Products | DAQ Devices, Accessories & Add‑Ons, Accessories, Data Acquisition (DAQ) Devices, T-Series Devices, LabJack UD Devices, Temperature Probes |
| Number of products | 36 |
| Product prices | $6–$1,400 |
| Last product update | 22 November 2026 |
| Ships to | Worldwide |
| Returns information | https://labjack.com/pages/returns-form |
| Review profiles | Trustpilot |
| Social profiles | X · Facebook · YouTube · LinkedIn |
| Logo | https://labjack.com/cdn/shop/files/LabJack_Logo_fa79278b-4a0c-4e5e-8ed7-dff9ad5b8dbb.png?v=1656709585&width=744 |
| Image | http://labjack.com/cdn/shop/files/OG_image.jpg?v=1655840588 |
About
55 of 55 LabJack Products are In Stock for Immediate Shipping Computer-based DAQ expertise delivering successful outcomes and strong partnerships with companies large and small since 2001 Email & Live Chat Responses that actually answer your question.
Services
- Legendary Support
- Flexibility
- Returns and Repairs
- Refund policy
- Withdraw from contract
- Flexibility
- Our engineers speak directly.
- Just the information you need to make an informed choice.
- No marketing fluff, no empty promises
Frequently asked questions
- Shop
- DAQ Devices Accessories Compare LabJacks
- Support
- Datasheets Device Support Home App Notes Quickstart Tutorials Software-API-Examples
- Legendary Support
- Legendary Support Flexibility Solutions over Show
- What does 12- or 16-bit resolution mean?
- Resolution refers to the process of converting an analog voltage into a digital value, which a computer can store and manipulate. The number of bits used in this conversion determines the resolution of the device. For example, a 2-bit device can store 4 different values, while a 12-bit device can store 4096 different values. However, the number of bits alone doesn't indicate the quality of the conversion. It's important to consider factors like inherent noise and effective resolution when evaluating a device's performance. Some devices may be advertised as having a high number of bits, but act
- What is a LabJack?
- LabJacks are USB/Ethernet/WiFi based measurement and automation devices which provide analog inputs/outputs, digital inputs/outputs, and more. A LabJack is an essential part of a computer-based instrumentation. If you want to make a computer-based system that acquires readings from various sensors/transducers, and controls various outputs/actuators, you need a LabJack to go between the computer and the various inputs and outputs. Go to our main FAQ page for more basic questions like 'What is DAQ (data acquisition)' and 'What is an analog input'.
- What is DAQ (data acquisition)?
- DAQ is short for data acquisition, which is short for data acquisition and control. The term describes the process of acquiring readings from sensors and transducers (temperature, pressure, strain, etc.), and controlling actuators (relays, solenoids, etc.). In our case the emphasis is on computer-based DAQ, where the LabJack is the interface that allows a computer to read from sensors and control actuators.
- What is an amplifier, PGA or PGIA?
- A PGA (Programmable Gain Amplifier) provides variable gain which is controlled in software. It is used to amplify low voltages on analog inputs. Most LabJacks have an internal PGA that can be used to provide small gains in some situations, but for larger gains an external amplifier must be used.
- What is a counter?
- A counter generally increments an internal register each time a voltage pulse is detected at the counter input. This internal register is then read periodically to determine how many events have occurred. Typically used to measure frequency or RPM, accumulate pulses from a tipping bucket precipitation (rain) gauge, and similar counting applications.
- What is an analog output (AO, DAC)?
- AO = Analog Output DAC = Digital to Analog Converter The LabJack's analog outputs convert digital values from a computer into a variable voltage level presented on an output terminal. This provides an adjustable output.
- What are digital I/O? (IO, D, DIO, FIO, EIO, CIO, MIO)
- Digital Input/Output, also known as DIO, refers to a feature of microcontrollers that allows them to detect logic states and output logic states. Digital Inputs detect if a voltage is above or below a specific threshold, and Digital Outputs allow a microcontroller to control a voltage output. LabJacks are devices that have DIO ports, and these ports may be labeled with different names such as IO, D, FIO, EIO, CIO, or MIO, depending on the specific device. Each digital I/O port can be configured as an input or output, and further configured as either high or low output.
- Where Are LabJack Datasheets?
- To access LabJack Datasheets, go to the Support Tab and select Datasheets from the Table of Contents. This will give you access to all the available LabJack Datasheets.
- New to Data Acquisition (DAQ)? Where to Start?
- Talk to an experienced LabJack staff member or engineer at a mutually convenient time. Or try chatting online right now! Our engineers provide real-time live chat Monday-Friday between 9AM-11AM and 2PM-4PM Mountain Time.
- What should I do if my analog input is stuck on some wrong value?
- To troubleshoot an analog input that is stuck on the wrong value, check the connections and signal, verify the device configuration and settings, check for noise, and calibrate the device if necessary. If the problem persists, contact the manufacturer or consult the device manual for further help.
- What should I do if my analog input is returning varying values but not the correct value?
- To troubleshoot an analog input that returns varying values instead of the correct value, check the wiring, signal source, device configuration, and settings. Apply signal conditioning and calibrate the device if necessary. Contact the manufacturer or refer to the device manual if the issue persists.
- What do I need to do if my readings are too noisy?
- To troubleshoot noise, start by confirming the expected noise level using the Ground Test from the Test an AIN Channel App Note. Connect your signal and compare the noise level to the expected level. If the LabJack has the expected noise level, troubleshoot the signal. To do this, use raw voltages, remove all connections except power/comm and the signal you're troubleshooting, and evaluate noise over a short period of time. Use known software provided by LabJack to avoid introducing changes to the signal.
- How do I measure temperature using a thermocouple, RTD, thermistor or other?
- For temperatures ranging from -50 to +150°C, a silicon temperature sensor is the cheapest, easiest, and most accurate solution. Thermocouples are best beyond silicon sensors. Thermistors and RTDs may seem accurate but measuring resistance accurately can be difficult. Digital sensors are a great solution depending on the LabJack and software used. Older devices require software that makes specific calls to the UD or U12 library, while other sensors require specific calls to the LJM, UD, or U12 library.
- What should I do if my thermocouple readings are incorrect?
- To troubleshoot thermocouple readings, you should determine if the error is from the cold junction sensor, A/D conversion, or the signal itself. If the cold junction reading is off, it will affect the calculated thermocouple temperature. To isolate the issue, you can remove the thermocouple and jumper the analog input to GND, which should give a 0.0V reading. Another option is to remove the thermocouple and measure the air temperature near the LabJack. The expected voltage will depend on whether the terminals being connected to are at air temperature or warmer.
- How can I monitor a 4-20 mA current loop signal or measure other currents?
- LabJack analog inputs measure voltage. The LJTick-CurrentShunt is an easy way to convert 4-20 mA to voltage.
Features
- Wi-Fi
- Multilingual
What they sell
Web shop on Shopify: 36 products, $6–$1,400. Sells: All LabJack Products | DAQ Devices, Accessories & Add‑Ons, Accessories, Data Acquisition (DAQ) Devices, T-Series Devices, LabJack UD Devices, Temperature Probes.
- DC-DC Power Adapter: $20 (in stock) · image
- LJTick-InAmp 3: $75 (in stock) · image
- LabJack U3-LV: $135–$160 (in stock) · image
- LabJack U6-Pro: $450–$490 (in stock) · image
- LabJack T7-Pro: $790–$850 (in stock) · image
- LabJack T4: $220–$305 (in stock) · image
- LabJack U6: $400–$445 (in stock) · image
- LabJack U3-HV: $135–$160 (in stock) · image
- LabJack U12: $225–$240 (in stock) · image
- LabJack T7: $520–$570 (in stock) · image
- Calibration Service with Certificate for U6/UE9/T7/T8: $100 (in stock) · image
- RB16 Relay Board: $210 (in stock) · image
Verification
Unclaimed · Not verified by owner. Nobody has claimed this listing yet, so no fact has been confirmed by the business itself. Verification state: unclaimed.
Key facts on this card: 10 of 11; missing: Opening hours. AI-ready (at least 8 of 11 key facts filled in).
Is this your business? Claim this listing (free: prove you control the website, and the badge changes to “Verified by owner”). What claiming means.
Where these facts come from
Read from labjack.com. Last checked 22 November 2026 (39 h ago); last changed 39 h ago; listed since 22 November 2026. Every listing is re-checked about every 7 days.
| Fact | Found in | Page |
|---|---|---|
| Name | structured data | / |
| Summary | page metadata | / |
| About | page text | /pages/about |
| Address | page text | /pages/contact |
| City | page text | /policies/terms-of-service |
| Map location | page text | /pages/contact |
| Phone | page text | /pages/contact |
| page text | /pages/contact | |
| Services | page text | /, /pages/contact, /pages/tech-support, /pages/about, /policies/terms-of-service, /pages/frequently-asked-questions, /pages/returns-and-cancellations, /blogs/faq/why-labjack, /blogs/faq/international-labjack-distributors |
| FAQs | structured data | /, /pages/contact, /pages/tech-support, /pages/about, /policies/terms-of-service, /pages/frequently-asked-questions, /pages/returns-and-cancellations, /blogs/faq/why-labjack, /blogs/faq/international-labjack-distributors |
| Features | page text | /pages/about, /policies/terms-of-service, /pages/frequently-asked-questions |
| Payment methods | page text | /pages/frequently-asked-questions |
| Languages | page metadata | /, /pages/contact, /pages/tech-support, /pages/about, /policies/terms-of-service, /pages/frequently-asked-questions, /pages/returns-and-cancellations, /blogs/faq/why-labjack, /blogs/faq/international-labjack-distributors |
| Founded | page text | /pages/about |
| Logo | structured data | / |
| Image | page metadata | / |
| Social profiles | structured data | /, /pages/contact, /pages/tech-support, /pages/about, /policies/terms-of-service, /pages/frequently-asked-questions, /pages/returns-and-cancellations, /blogs/faq/why-labjack, /blogs/faq/international-labjack-distributors |
| Contact page | page text | / |
| Pricing page | page text | /pages/frequently-asked-questions |
| Returns information | page text | / |
| Review profiles | page text | /pages/about |
| Category | page text | / |
| Web shop | page metadata | / |
| Shop platform | page metadata | / |
| Currency | shop platform data | /products.json |
| Shop status | shop platform data | /products.json |
| Number of products | shop platform data | /products.json |
| Country | shop platform data | /meta.json |
| Region | shop platform data | /meta.json |
| Ships to | shop platform data | /meta.json |
| Last product update | shop platform data | /products.json |
| Product prices | shop platform data | /products.json |
| What they sell | shop platform data | /products.json |
Recent checks
- 39 h ago: Added to the directory
More in Shops & Retail
Links
- Markdown fact card · JSON fact card (every fact with its source) · llms.txt · API · products API · documentation, OpenAPI and the MCP server
- Report this listing · Ask for removal
How to use this site as an agent
| This page as Markdown | https://aifindme.com/b/labjack.md (or send Accept: text/markdown to this address) |
|---|---|
| This page as JSON | https://aifindme.com/b/labjack.json (or Accept: application/json) |
| This page as llms.txt | https://aifindme.com/b/labjack/llms.txt |
| This page through the API | https://aifindme.com/api/v1/businesses/labjack |
| Start here | https://aifindme.com/agents: what a fact card guarantees, the three ways to query, rules and rate limits, freshness, how to add or correct a business. Long form: https://aifindme.com/for-ai-agents |
| Search API | GET https://aifindme.com/api/v1/businesses?q=…&category=…&city=…&kind=shop&verified=1&open=now · OpenAPI · documentation |
| MCP server | POST https://aifindme.com/mcp (Streamable HTTP, no key): search_businesses, get_business, get_products, list_new_listings, list_categories, list_cities |
| Directory index | https://aifindme.com/llms.txt: every category and city with counts, and the latest listings · https://aifindme.com/llms-full.txt: one compact entry per listing |
| Agent skill | https://aifindme.com/skills/aifindme/SKILL.md: when and how to use this directory and how to cite it (Agent Skills format) |
| Views | Add ?view=ai or ?view=human to any address. Both carry the same facts and links; only the presentation differs. |