Microflex in Pattison
Shops & Retail in Pattison · Web shop on Shopify · Unclaimed · Not verified by owner · facts last checked 22 November 2026 · read from microflx.com.
Facts
| Name | Microflex |
|---|---|
| Category | Shops & Retail |
| Summary | Reliable HART protocol modems and RS-485 converters plus innovative solutions and tools for the process industry. Gas cylinder sampling heaters. |
| Website | microflx.com |
| Address | MicroPulser 1000 CW/CCW Outputs |
| City | Pattison |
| Region | Texas |
| Country | United States |
| Map location | Map |
| Payment methods | iDEAL |
| Web shop | Web shop on Shopify: 37 products, $6.95–$1,156.95 |
| Currency | USD |
| What they sell | HART® Protocol Modems, HM HART Protocol Modems with Modbus Accumulator, RS-485 Converters, Accessories, GCH Gas Sampling, InLink OEM HART Protocol Modem Modules, MicroPulser Gas Meter Volume Pulsers, PixelSigns Display Accessories |
| Number of products | 37 |
| Product prices | $6.95–$1,156.95 |
| Last product update | 22 November 2026 |
| Ships to | Worldwide (55 countries) |
| Shipping information | https://delivery.shopifyapps.com/-/0246232e998f61ce/52efb1336cc2a399 |
| Image | https://cdn.shopify.com/s/files/1/0555/4461/files/Microflex1200x628.jpg?v=1744724446 |
About
Modems provide a simple communications link to HART® devices (Highway Addressable Remote Transmitter). Cable and DIN mount HART protocol modems with USB and RS-232 interfaces are available. HM HART modems provide Modbus-RTU support. InLink HART modem modules are for OEM embedded applications. HM Series HART protocol modems can be used as a standard HART configuration modem or setup as a HART master to continuously poll HART devices storing variable data into modbus registers. Modbus commands can read HART device variables. HM configurator and HART device addresser software apps included free.
Services
- HART Protocol Modems · MicroLink HART protocol modems provides a simple link between a PC and HART® (Highway Addressable Remote Transmitter) devices. All are HART compliant and maintain compatibility with HART software. Included USB software drivers make the USB
- RS-485 Converters · Microflex RS-485 converters easily connect to your two wire RS-485 device and convert to either RS-232 or USB. They feature auto transmit control and do not require RTS (request-to-send) for direction control. Glitch-free power up/down perm
- Natural Gas Spot Sampling Equipment · 2KC Solutions natural gas spot sampling products.
- Gas Meter Volume Pulser · MicroPulser™ is a precision microprocessor based dual channel flow rate transmitter designed to be installed between the meter and vertical index, or instrument on most industrial/commercial gas flow meters.
- HART Protocol Host App, Class 3 Basic · Fast, Simple Setup for HART field devices Microflex HART Host Class 3B is a software app for Windows based PCs used to commission and calibrate HART field devices. HART Host is compatible with all Microflex HART protocol modems and all HART
- USB MicroLink HART Protocol Modem · The USB MicroLink HART modem provides the hardware interface between Highway Addressable Remote Transducer devices, HART®, and a Windows® PC with a USB port. Universal Serial Bus (USB) drivers make MicroLink compatible with most software de
- USB-C MicroLink HART Protocol Modem · The USB-C MicroLink modem provides the hardware interface between Highway Addressable Remote Transducer devices (HART®) and a Windows® PC with a USB port. Universal Serial Bus (USB) drivers make MicroLink compatible with most software devel
- RS-232 MicroLink HART Protocol Modem · The RS-232 MicroLink modem provides a simple low-cost interface between Highway Addressable Remote Transducer (HART) protocol devices and any computer with an RS-232 serial port. MicroLink was designed to comply with the HART physical layer
- MicroLink HART Protocol Modem - USB Interface · USB MicroLink HART protocol modem, DIN mount, provides the hardware interface between Highway Addressable Remote Transducer devices (HART®) and a Windows® PC with a USB port. Universal Serial Bus (USB) drivers make MicroLink compatible with
- MicroLink-HM+ USB/RS-485/RS-232 HART Modem with Modbus Accumulator · MicroLink-HM+ is a HART® protocol modem to USB/RS-485/RS-232 serial interface. In addition to functioning as a HART protocol modem, it can also be configured to continuously poll HART devices, filling Modbus registers with device values wit
- MicroLink-HM HART Protocol Modem + Modbus Accumulator, RS-485 Interface · The MicroLink-HM RS-485 is a managed HART modem that can be used as a primary or secondary HART host interface - eliminating the need for external carrier detect (CD) monitoring and request-to-send (RTS) control. It can also be configured t
- MicroLink-HM HART Protocol Modem + Modbus Accumulator, RS-232 Interface · MicroLink-HM RS-232 is a managed HART modem that can be used as a primary or secondary HART host interface - eliminating the need for external carrier detect (CD) monitoring and request-to-send (RTS) control. It can also be configured to co
- Field Tools Loop Power · The Field Tools Loop Power provides portable power to loop-powered 2-wire transmitters for commissioning and testing. It's a fully contained power source that takes the low voltage from three "AAA" alkaline batteries and increases it to a h
- Field Tools Loop Tap · Loop Tap makes connecting to 2-wire 4-20 mA current loop devices easy and simple. Commission and calibrate your devices faster with increased reliability by eliminating test leads and alligator clips from your test setup. Loop Tap includes
- InLink-CC™ HART Modem Module - Capacitor Coupled · InLink-CC is a HART protocol modem module that modulates logic level 1200 BAUD serial data onto a HART loop, and demodulates received HART data providing a 1200 BAUD serial bit stream. It allows designers to easily implement a HART complian
- InLink-TC™ HART Modem Module - Transformer Coupled · InLink-TC is a HART protocol modem module that modulates logic level 1200 BAUD serial data onto a HART loop, and demodulates received HART data providing a 1200 BAUD serial bit stream. InLink-TC interfaces to standard 3.3V to 5V logic and o
- InLink-HM OEM HART Protocol Modem with Modbus Registers · InLink-HM is a complete HART modem module that can be used as a primary or secondary HART host - eliminating the need for external carrier detect (CD) monitoring and request-to-send (RTS) control. It can also be configured to continuously p
- Case - Soft-sided · Soft-side zipper-top product case (7" w x 6" h x 2 d"). Super soft black faux fur interior lining. Front pouch is unlined. Side clip on left and a pen holder on the right side.
- USB-A to USB-B Cable (2 meter) · USB-A male to USB-B male extension cable. Can be used to connect modems and converters with standard USB-B type connectors to a computer with a USB-A port. USB 2.0 compliant.
- USB Extension Cable (2 meter) · 2 meter USB-A male to USB-A female extension cable. Can be used with USB modems and converters to increase the cable length. USB 2.0 compliant.
- RS-232 Extension Cable (6ft) · RS-232 DB9 male to DB9 female extension cable, 6 feet long.Can be used with RS-232 modems and converters to increase the cable length.
- InLink- Evaluation Board · The 101-0003 InLink evaluation board provides product developers the ability to quickly evaluate InLink HART protocol modems. Socket supports all InLink modules to provides a simple RS-232 to HART interface compatible with most off-the-shel
- InLink-HM Evaluation Board · Evaluate InLink-HM HART modem modules using RS-485 communications. Evaluation board provides a simple RS-485 to HART interface compatible with most off-the-shelf HART protocol software including PACTware and the Microflex Generic HART DTM.
- HM Configuration Software App · Configure MicroLink-HM Modems HM Configurator is a Microsoft Windows app used to setup and configure the Microflex HM series of HART protocol modems. HM modems can be configured to continuously poll up to 16 HART devices, acquiring variable
- Rev 3.5 Contains...
- Add to Cart for access to the free download link after checkout.
Prices
| USB MicroLink HART Protocol Modem | €272,95 |
|---|---|
| USB-C MicroLink HART Protocol Modem | €272,95 |
| Field Tools Loop Power | €111,95 |
| Field Tools Loop Tap | €26,95 |
| Case - Soft-sided | €13,95 |
| InLink- Evaluation Board | €29,95 |
| InLink-HM Evaluation Board | €29,95 |
| HART Products Setup Utility | €0,00 |
| HM Configuration Software App | €0,00 |
| Gas Spot Sampling Valve | €1.156,95 |
| SSV Seal Service Kit | €16,95 |
| Default Title | €0,00 |
| Top Spinner Cover Kit | €9,95 |
Frequently asked questions
- What is HART?
- The HART Communication Protocol (HART = Highway Addressable Remote Transducer) defines a bi-directional field communication protocol standard for instrument, control and automation systems. Actually, it's not just a standard, but the global standard for sending and receiving digital information across analog wires between smart devices and host systems. A host can be any software application from technician's hand-held device or laptop to a plant's process control, asset management, safety or other system using any control platform.
- Why use HART Technology?
- There are several reasons for using HART Communication to enhance the data flow between hosts and field devices. These include device (re)configuration, diagnosing and troubleshooting instruments, reading values of additional measurements provided by the device, and much more. It can provide many benefits, including playing a major role in improving plant operations, increasing asset availability, reducing maintenance costs and aiding in regulatory compliance. In all these roles, HART technology has proven to be easy to use and very reliable. For more information on the features and benefits o
- How does HART Communication work?
- The HART Protocol provides two simultaneous communication channels on the same wire: 4-20mA “current loop” analog and a HART digital signal. While the analog signal continues to provide primary values to and from field instruments, the digital signal provides additional device information. This is a very robust method with roots in the Bell 202 Frequency Shift Keying (FSK) standard, which originally superimposed a digital communication signal "on top of" the 4-20mA current loop to bring Caller ID technology to the field of telephony.
- What is a Device Description?
- Key to the HART Protocol's ability to "get data out of the field device" is a data file called a Device Description (DD). This describes the features and functions of a device, such as the form and content of menus and graphic displays to be presented in host computers or handheld devices. The DD is written in conformance with a Device Description Language in the protocol. The HART Communication Foundation manages a library of Manufacturer Device Descriptions, and provides regular updates to which any Foundation member can subscribe. DD’s are available for download at the HART Communication Fo
- Can PACTware use DDs instead of DTMs?
- PACTware does not support DDs directly, but there are several software tools available on the market which convert DDs into DTMs to be used in FDT frames like PACTware.
- How can I use devices which do not have their own DTM?
- In this case Generic DTMs can be used to configure most of the parameters. Microflex HART protocol modems include the fully licensed Generic HART DTM-4.
- Is the Generic HART DTM contained in the instrument or are the definitions located somewhere else?
- The Generic DTM supports the HART commands which are common to all HART instruments (Universal and Common Practice commands). A typical instrument will contain device specific commands that will require a more device specific DTM for full support.
- What Protocols does PACTware support?
- PACTware supports all common communication protocols by adding the specific protocol layer. Microflex modems ship with PACTware and the HART communications protocol layer.
- What is the main difference between DTM and DD configuration methods?
- The FDT standard supports both DD and DTM configuration methods.
- What is the FDT Technology?
- FDT Technology standardizes the communication interface between field devices and control systems or engineering and asset management tools. Key features are its independence from the communication protocol and the software environment of either the device or the host system. FDT Technology allows any device to be accessed from any host through any protocol.
- What is the FDT Interface?
- The FDT interface specification describes the standardized data exchange between devices and control systems or engineering and asset management tools. Devices can be configured, operated, and maintained through the standardized user interfaces integrated in an FDT Frame Application.
- What is a Device Type Manager (DTM)?
- A Device Type Manager (DTM) is part of the FDT standard that is a software component for a device that contains the device-specific data, functions and logic elements. DTMs can reach from a simple graphical user interface for setting device parameters up to a highly sophisticated application that, for example, can perform complex calculations for diagnostics and maintenance purposes or can implement arbitrarily complex business logics for device calibration.
- Which communication protocols does FDT Technology support?
- The FDT specification supports the communication protocols AS-interface, CANopen, CIP Annex Configuration, ControlNet, DeviceNet, EtherNet/IP, FOUNDATION Fieldbus, HART, INTERBUS, IO Link, MODBUS SL/TCP, PROFIBUS DP/PA, and PROFINET I/O.
What they sell
Web shop on Shopify: 37 products, $6.95–$1,156.95. Sells: HART® Protocol Modems, HM HART Protocol Modems with Modbus Accumulator, RS-485 Converters, Accessories, GCH Gas Sampling, InLink OEM HART Protocol Modem Modules, MicroPulser Gas Meter Volume Pulsers, PixelSigns Display Accessories.
- SSV Seal Service Kit: $16.95 (in stock) · image
- USB-C to RS-485 Converter: $109.95 (in stock) · image
- USB-C MicroLink HART Protocol Modem: $272.95 (in stock) · image
- HART Protocol Host App, Class 3 Basic: $62.95 (in stock) · image
- Field Tools Loop Tap: $26.95 (in stock) · image
- MicroLink-HM+ USB/RS-485/RS-232 HART Modem with Modbus Accumulator: $355.95 (in stock) · image
- RS-232 to 2-Wire RS-485 Converter, Isolated, DIN Rail Mounted: $119.95 (in stock) · image
- InLink-HM Evaluation Board: $29.95 (in stock) · image
- RS-232 Female to Wire - 3 Conductor: $11.95 (in stock) · image
- Screwdriver - Precision Slotted 2mm Blade: $6.95 (in stock) · image
- MicroLink-HM HART Protocol Modem + Modbus Accumulator, RS-485 Interface: $310.95 (in stock) · image
- InLink-HM OEM HART Protocol Modem with Modbus Registers: $127.95 (in stock) · image
Verification
Unclaimed · Not verified by owner. Nobody has claimed this listing yet, so no fact has been confirmed by the business itself. Verification state: unclaimed.
Key facts on this card: 6 of 11; missing: Contact details, Opening hours, Features, Social profiles, Booking, order, menu or pricing link. Not yet AI-ready (fewer than 8 of 11 key facts).
Is this your business? Claim this listing (free: prove you control the website, and the badge changes to “Verified by owner”). What claiming means.
Where these facts come from
Read from microflx.com. Last checked 22 November 2026 (11 h ago); last changed 11 h ago; listed since 22 November 2026. Every listing is re-checked about every 7 days.
| Fact | Found in | Page |
|---|---|---|
| Name | page metadata | / |
| Summary | page metadata | / |
| About | page text | / |
| Address | page text | /collections/gas-meter-volume-pulsers |
| Services | page text | /pages/products, /collections/hart-protocol-modems, /collections/hm-hart-protocol-modem-with-modbus-accumulator, /products/hart-setup |
| Prices | page text | /collections/hart-protocol-modems, /collections/hm-hart-protocol-modem-with-modbus-accumulator, /collections/rs-485-converters, /collections/gas-sampling-equipment, /products/hart-setup, /collections/gas-meter-volume-pulsers |
| FAQs | page text | /pages/faq |
| Payment methods | page text | /pages/products |
| Image | page metadata | / |
| Shipping information | page text | /products/hart-setup |
| Category | page text | / |
| Web shop | page metadata | / |
| Shop platform | page metadata | / |
| Currency | shop platform data | /products.json |
| Shop status | shop platform data | /products.json |
| Number of products | shop platform data | /products.json |
| Country | shop platform data | /meta.json |
| City | shop platform data | /meta.json |
| Region | shop platform data | /meta.json |
| Ships to | shop platform data | /meta.json |
| Last product update | shop platform data | /products.json |
| Product prices | shop platform data | /products.json |
| What they sell | shop platform data | /products.json |
Recent checks
- 11 h ago: Added to the directory
Links
- Markdown fact card · JSON fact card (every fact with its source) · llms.txt · API · products API · documentation, OpenAPI and the MCP server
- Report this listing · Ask for removal
How to use this site as an agent
| This page as Markdown | https://aifindme.com/b/microflex.md (or send Accept: text/markdown to this address) |
|---|---|
| This page as JSON | https://aifindme.com/b/microflex.json (or Accept: application/json) |
| This page as llms.txt | https://aifindme.com/b/microflex/llms.txt |
| This page through the API | https://aifindme.com/api/v1/businesses/microflex |
| Start here | https://aifindme.com/agents: what a fact card guarantees, the three ways to query, rules and rate limits, freshness, how to add or correct a business. Long form: https://aifindme.com/for-ai-agents |
| Search API | GET https://aifindme.com/api/v1/businesses?q=…&category=…&city=…&kind=shop&verified=1&open=now · OpenAPI · documentation |
| MCP server | POST https://aifindme.com/mcp (Streamable HTTP, no key): search_businesses, get_business, get_products, list_new_listings, list_categories, list_cities |
| Directory index | https://aifindme.com/llms.txt: every category and city with counts, and the latest listings · https://aifindme.com/llms-full.txt: one compact entry per listing |
| Agent skill | https://aifindme.com/skills/aifindme/SKILL.md: when and how to use this directory and how to cite it (Agent Skills format) |
| Views | Add ?view=ai or ?view=human to any address. Both carry the same facts and links; only the presentation differs. |