Ortofon is a micro-mechanical powerhouse, which develops, manufactures and markets the world acclaimed Ortofon phono cartridges.

The facts
- Address
- 500 Executive Blvd, Suite 102, 10562 Ossining, NY, United States Map
- Country
- United States
- Phone
- +19147628646
- support@
ortofon. us - Founded
- 1918
- Languages
- English, Spanish
- Ships to
- Worldwide (27 countries)
- Shipping information
- Shipping page
- Returns
- within 14 days Returns page
What they sell
Web shop on Shopify: 281 products, $6.99–$16,999.99
Show 17 more categories
Concorde MKII Elite - Twinset$923.99In stock
MC 90X$5,769In stock
MC X50$1,699.99In stock
MC Vertex$16,999.99In stock
SH-2 Black$36.99In stock
HiFi Care Accessory Pack$83.99In stock
Stylus VNL DANCE$89.99In stock
Stylus VNL TRIX$65.99In stock
VNL DANCE Premounted$199.99In stock
VNL DANCE$159.99In stock
VNL TRIX$129.99In stock
VNL TRIX Premounted$169.99In stock
12 of 281 products, read 2 h ago
12 of 281 products, prices $6.99–$16,999.99, as published by the shop (read from the shop 2 h ago; the shop last changed its products 28 November 2026; last change seen here 6 days ago). Prices and stock change; the shop’s website has the current ones.
About
Today, Ortofon is a micro-mechanical powerhouse, which develops, manufactures and markets the world acclaimed Ortofon phono cartridges. We benefit from being established in Denmark, a country recognized for its strong tradition in acoustics and acoustic measurement equipment, in addition to all aspects of high-end audio. Acoustics, materials, technology and micro mechanics are key competences in Ortofon's technological prowess. Research and development is done with the company's own engineers supported by a strong network of acoustic know-how and industrial design in Denmark.
Frequently asked questions
Need help?
Search Find the right cartridge Contact FAQ Support Articles
Stylus and record care
To maintain optimal sound reproduction and to minimize wear on your record as well as on your stylus, we recommend the following procedure before and after each playback:• Remove dust carefully from record surfaces by using Ortofon antistatic Record brush before every use. Use Ortofon Stylus fiber brush a few times along the cantilever in the direction of the stylus tip, whenever you play a new record or change sides. Use the brush in the forward direction from the rear of the cartridge towards the stylus tip and never from stylus tip to the rear of the cartridge and never from side to side.…
Stylus lifetime
With proper care we find that up to 1000 hours is possible without degradation of performance.You can learn more about stylus lifetime and how to get the most out of your records here. Proper care comprises the following:Cleaning of record by means of fibre brush before and after every use. Cleaning of record by using record cleaning machine once in a while. Cleaning of stylus by means of a fine antistatic brush. Please remember to remove dust from the diamond tip before and after playback of each record. Use the brush in the forward direction from the rear of the cartridge towards the stylus…
Styli types
There are several different diamond shapes with various properties, and each of them are crucial factors for sound quality.For more information about Diamonds and Styli types please here.
Leads connections
All Ortofon cartridges have a color coding of the terminals, indicating red and green for right channel, respectively hot and ground terminal. White and blue for left channel, respectively hot and ground terminal. Green terminal will always be used for grounding the cartridge housings or motor-system whenever connected inside the cartridge.We recommend to connect lead wires to the cartridge and headshell before mounting the cartridge on the headshell. Please remember correct orientation of the leads. Ortofon SH-4 headshell and Ortofon cartridges' terminal PINs diameter is 1.2 mm, while…
Azimuth, vertical alignment
Azimuth adjustment or vertical alignment of the cartridge is very important for optimal channel separation.The checking is easily done by lowering the cartridge onto a thin mirror placed on the record surface and examining whether the reflection lines up square with the cartridge, when viewed from the front. During this test tonearm must still be parallel to the record surface. If not obtainable because of mirror thickness, remove record and work directly on the mat. If alignment is still incorrect and not adjustable because of fixed headshell, the only solution is to resort to packing on one…
Tonearm level, Vertical Tracking Angle (VTA)
Cartridges are constructed so that cantilever angle corresponds to the 20 deg. record cutting angle, when the cartridge is loaded with recommended tracking force and the cartridge base is parallel with the tonearm and this again is parallel to the record surface.0.5 mm clearance between the cartridge base line and record surface is the acceptable minimum.
Compatibility with Rega brand TT/TA
The Rega tonearms are installed for the height of Rega cartridges, these cartridges’ height from stylus tip to the top of the cartridge mounting surface is lower than standard. When choosing a Moving Magnet cartridge, our recommendation is the 2MR models that are designed for this specific height requirements.Since it is vital to ensure that the cartridge base is parallel with the tonearm and the tonearm is parallel with the record surface, you will need spacers to ensure the correct setup for other Ortofon cartridges than 2MR.Spacers below the Rega tonearm base is needed for this.Rega offers…
Anti-skating, bias compensation adjustment
Correct bias or anti-skating adjustment is important in order to achieve optimal tracking ability and thereby minimum record wear and distortion. A number of players have a device which, related to the tracking force, will give an anti-clockwise force needed to the tonearm. Correct bias has to compensate for the inwards directed torque on the tonearm caused by the friction between stylus and groove. But this again is influenced by stylus type and amplitudes in the record.A simple recommendation for a rather precise bias: if you hear distortion in say right channel when using recommended…
Tonearm / cartridge combination
When choosing either MC or MM cartridges for your record player, total mass of tonearm including cartridge and headshell has to be taken into account in relation to the mechanical compliance (elasticity) of the cartridge cantilever system.Find more information here.Meaning that high mass of the combination needs low mechanical compliance, otherwise record warps can easily provoke tonearm vibrations at frequencies around 4 to 6 Hz, that will bring degradation of performance. At least 8 Hz is advisable.To choose the right cartridge for your turntable/tonearm please seeour Replacement cartridges…
Break-in
A "break-in" period of up to 20 hours of normal playback has to be allowed in order to get the best performance.
User guides
MC Cadenza SeriesMC Cadenza Series user guideMC Quintet SeriesMC Quintet Series user guideConcorde MusicConcorde Music user guideStylus Concorde Music user guide2M Series2M user guide2MR user guide 2M Premounted user guide2M Verso user guideStylus 2M user guideConcorde MKIIConcorde MKII user guideStylus Concorde MKII user guideVNL SeriesVNL Premounted unser guideStylus VNL user guideOM and Concorde MKIHiFi Stylus OM and Concorde MKI user guideDJ Stylus OM and Concorde MKI user guideDJ OM Premounted cartridge Stylus 300 and 500 seriesStylus 300 and 500 user guide
Contact problems
Phono cartridges rely on good electrical contact between the cartridge pins and the tonearm leads. If you’re experiencing sound issues or interruptions, this may be due to a contact problem. Here’s what you can do:Check Connections: Make sure the cartridge pins are securely connected to the tonearm leads. Dust, oxidation, or loose connections can cause contact problems.Clean Pins and Leads: Carefully clean the cartridge pins and tonearm connectors using a soft, lint-free cloth or a specialized contact cleaner. Avoid abrasive materials, which could damage the pins.
Distortion
Distortion typically suggests that the stylus may be worn or damaged. When this occurs, you might notice increased distortion when listening to voices and string instruments, particularly toward the inner grooves of records. High frequencies can also lose clarity and transparency. If you notice these symptoms, the stylus likely needs replacement.Distortion in sound—such as crackling, hissing, or unwanted noise—can arise from various issues within your phono cartridge system. Below are common causes and ways to troubleshoot them:Stylus Condition: A worn or damaged stylus often causes sound…
How to replace stylus in the Moving Magnet cartridge?
Firstly lock the turntable tone arm, unscrew the cartridge, gently remove the stylus from the cartridge body and insert a new stylus. A stylus is changed usually by pulling straight out and in the opposite direction of the turntable's arm. If the stylus doesn't come with direction, try these: with one hand, hold the cartridge to steady it. With the other hand grasp the stylus from both sides and pull. Install the new stylus. Holding the stylus from the top, press it gently into the space at the tip of the cartridge where the old stylus had been. Don't force it.
How to select the right cartridge for your particular record player?
When selecting either MC or MM cartridges for your record player, the total effective mass of tonearm (including tonearm effective mass, cartridge and headshell) has to be taken into account in relation to the mechanical compliance (elasticity) of the cartridge cantilever system.The rule of the thumb regarding the match between toneram mass and cartridge compliance goes like this: High mass requires low compliance, low mass makes it possible to benefit from high compliance.Read more about cartridge and tonearm systems resonance frequency and learn how to calculate compatibility of the system…
Can Concorde cartridge be used on straight-arm turntable?
First of all, straight arm DJ turntables are designed strictly for sheer groove-holding capability, and not for fidelity. Harmonic distortion on a short, straight tonearm will increase by double, which can limit the effectiveness of any great sounding cartridge, regardless of manufacturer. Using a Concorde cartridge will work fine, granted that is a spherical stylus. It should be noted that an elliptical stylus will likely not sit properly within the groove, and may result in unbalanced sound reproduction on this type of tonearm.
Can I angle my cartridge to crudely emulate a straight tonearm?
The practice of angling the cartridge 23 degrees counterclockwise directly against the tonearm pivot is a practice that is sometimes performed to increase tracking. However, this will cause excessive wear to your vinyl and also your stylus. This will also result in diminished sound quality, and is not recommended.
How do I set up my turntable?
Our step-by-step tutorials will guide you through assembling and configuring your DJ gear like a pro. Whether you're using controllers or decks, we'll help you get the perfect setup to launch your mixing journey.Find the tutorials here
How to set tracking force to provide best performance?
DJs that use Technics 1200/1210 turntables may need to remove the small cylindrical sub-weight from the rear of the tonearm in order to achieve high enough tracking forces. This sub-weight is located directly on the rear of the tonearm, behind where the counterweight attaches. With the weight installed, Concorde cartridges will only be able to achieve 2 grams of tracking force.With this weight removed, Concorde cartridges will be able to achieve approximately 4.75 grams of tracking force. Additional weight can be applied by turning the counterweight backwards so that the number scale faces…
Read from ortofon.us. Last read 2 h ago. 9 of 11 key facts have a value; missing: opening hours, booking, order, menu or pricing link. Where these facts come from