AI Find Me Check my shop

Sentinel Performance Innovation

Online shop · Burnsville, United States · sprayrack.com

Unclaimed · Not verified by owner

ASTM and AAMA testing equipment for window and building envelope water and air intrusion testing. Sentinel Performance Innovation, previously RM Group, provides the industry standard testing equipment like the RainMaker, RainWand, WindMaker and SprayRack.

WebsiteCallDirectionsContact

Photo from the business’s website

The facts

Address
12213 Wood Lake Dr Burnsville, MN 55337 Map
Country
United States
Phone
952.471.2623
Email
info@sprayrack.com
Languages
English
Ships to
Worldwide (54 countries)

What they sell

Web shop on Shopify: 71 products

1. Rain Maker Spray Rack & Accessories3. Rain Wand & Accessories2. Wind Maker & Accessories5. Accessories7. Also Purchased Items4. Training6. Testing EquipmentFull-Service Calibration
12 of 71 products, read 5 days ago

12 of 71 products, as published by the shop (read from the shop 5 days ago; the shop last changed its products 23 November 2026; last change seen here 5 days ago). Prices are being read again; the shop’s website has them.

About

Sentinel Performance Innovation was founded with a singular mission: to provide the construction and building inspection industry with reliable, professional-grade water intrusion testing equipment that protects property owners and ensures building integrity. Our flagship product, SprayRack, represents years of engineering expertise and real-world testing experience. We understand that water intrusion is one of the most costly and damaging issues facing commercial and residential buildings today. That's why we've dedicated ourselves to developing testing equipment that delivers accurate, repeatable results that professionals can trust.

Frequently asked questions

When do I run the AAMA 501.2 vs. ASTM E1105?

Use AAMA 501.2 if:You are testing a non-operable curtain wall or storefront.You want a quick, daily Quality Control (QC) check on a sealant crew's work.You have a limited budget but want to ensure the primary joints are sealed.Use ASTM E1105 if:The project specifications require a certified performance rating.You are testing operable windows or doors.You need to simulate actual weather conditions (wind + rain) to diagnose a mysterious leak.You are performing formal Building Envelope Commissioning (BECx).AAMA 501.2Common Name : The Hose TestPrimary Tool : RainWandForce Applied : Kinetic…

How often should I calibrate my equipment?

All equipment should be calibrated every 6 months to match the standard and ensure the test run will be compliant. Please contact us for more information and our easy process that keeps you both up and running and accurate.

What do I need to do the AAMA 501.2 test?

You can use our RainWand device to run this test. To make it even easier to maintain a constant distance from the surface and easier to reach all of the testing area we also recommend the Boom Extension.Then you simply need a water source that can get you to 30 psi and you are set to go.

Why should I get my equipment calibrated?

To ensure you are meeting the test standards and your equipment is in good, safe working condition you should get it calibrated. As part of our calibration process we carefully inspect the unit for any current or on the verge of issues. We ensure all working parts are still in spec to ensure your testing is accurate.For that peace of mind and guarantee to your customer ensure you are keeping your equipment calibrated.All equipment should be calibrated every 6 months to ensure compliance with the standards.

What test is run on a window with no moving parts?

Run the AAMA 501.2 which requires windows with no moving parts to stand up to this more stringent standard.Our product for conducting this test is theRain Wand. It provides a strong and small area spray. The spray is strong enough to make an operable, or residential type window leak for sure, and possibly even damage the specimen. The only test specimen designed to withstand the AAMA 501.2 standard is a storefront type window, or a curtain wall.

How soon can I expect products to ship after being ordered?

We do our best to ship as quickly as possible. Most items will ship within 24 hrs, but it can occasionally take a few days to prepare your order. Shipping will depend on your selection from next day air to ground and depending on where you are will determine when you get your package.

What pressure do I run the Rain Maker SprayRack during a water spray test?

According the the ASTM standards for spray testing, you must run the spray rack at the same pressure it was ran during its calibration test. The Rain Maker comes with a calibration test result sheet which reveals all conditions the spray rack was under during the calibration test, including pressure, distance of nozzles from test surface and from each other.The standard calibration is done at 12 psi, 20" from the surface.

What do I do if I can't get up to 12 psi at the RainMaker for the spray test?

If you don't have enough pressure at the RainMaker to get to 12 psi then you will need a booster pump. See our product pages for options.

Can I use the RainWand to perform the ASTM E1105 or equivalent test?

The Rain Wand is specifically designed to perform the AAMA 501.2 test only on curtain walls or storefront type windows with no operable parts - meaning only a window that cannot be opened and closed. Using the Rain Wand to perform any other test will reveal nothing about the window's performance, and can potentially damage an operable window.

How large of a chamber can the Wind Maker handle?

There are too many variables involved to be able to calculate an answer to this question. However, the Wind Maker is equipped with a "variable speed auxiliary power outlet".If you need additional help in getting your chamber vacated, please check out our Boost product which increases the capacity of the Wind Maker for those large or leaky setups.

What is the difference between ASTM E 331 and E1105?

There are fundamental differences that are revealed in thetitles of each standard.These are identified with italics below:ASTM E 331 — Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure DifferenceASTM E 1105 — Standard Test Method for Field Determination of Water Penetration of Installed ExteriorWindows, Skylights, Doors, and Curtain Walls by Uniform or Cyclic Static AirPressure DifferenceOther differences:The E 331 describes the test specimen being affixed to the air chamberThe E 1105 describes the air chamber…

What should I do before test day to ensure a successful test?

There are important issues to cover with your client before theday of the test that you'll be performing for them. If these are not coveredahead of time and it's discovered on test day that the test cannot beperformed, it can be very costly.Water Supply - ensure there is a source with enough volume and pressure. You may need a booster pump, additional hoses, special fittings, etc.Accessibility - able to get to the test area without obstruction, it is prepared to test and anything in the affected area knows about the testing.Ensure the test specimen is of the type for that particular…

Read from sprayrack.com. Last read 5 days ago. 7 of 11 key facts have a value; missing: opening hours, features, social profiles, booking, order, menu or pricing link. Where these facts come from

Is this your shop?

This page was made automatically from sprayrack.com, and nobody has verified it yet. Claiming is free and needs no approval. Facts you confirm replace what we read and are labelled “business owner”.

Claim this listing

What claiming means

Where these facts come from

Read from sprayrack.com. Last read 5 days ago; last changed 5 days ago. Every listing is re-checked regularly. Nobody has claimed this listing yet, so no fact has been confirmed by the business itself.

Fields with a value: 7 of 11; a value was not checked by us. No field was entered by the owner. Known problems: Product prices are left out until the shop is read again: they may have been read in another currency.

The source of each fact

FactFound inPage
Namestructured data/
Summarypage metadata/
Aboutpage text/pages/about-us
Addresspage text/pages/contact
Phonepage text/pages/contact
Emailpage text/pages/contact
FAQspage text/pages/faq, /collections/all
Languagespage metadata/, /pages/contact, /pages/about-us, /pages/faq, /collections, /collections/all, /products/rain-maker-spray-rack, /products/wind-maker-plus-test-vacuum, /products/rain-wand-aama-501-2-kit
Logostructured data/
Imagepage metadata/
Contact pagepage text/
Categorypage text/
Web shoppage metadata/
Shop platformpage metadata/
Currencyshop platform data/products.json
Shop statusshop platform data/products.json
Number of productsshop platform data/products.json
Countryshop platform data/meta.json
Cityshop platform data/meta.json
Regionshop platform data/meta.json
Ships toshop platform data/meta.json
Last product updateshop platform data/products.json
What they sellshop platform data/products.json

Recent checks

For AI assistants and developers

schema.org data is embedded in this page. Facts last read 23 November 2026.

How often this listing is read

Since 25 November 2026:

The page and its machine copies count. Most AI crawlers copy pages that may train a model or fill a search index: such a read is not a person, a visitor or a recommendation. How we count

More in Shops & Retail

Report this listing · Remove this listing