AI Find MeAI view

Surge Protection Devices in Oldham: products, shipping and shop facts

Shops & Retail in Oldham · Web shop on WooCommerce · Unclaimed · Not verified by owner · facts last checked 23 November 2026 · read from surgedevices.co.uk.

Facts

NameSurge Protection Devices
CategoryShops & Retail
SummarySurge Protection Devices provide lightning and surge protection solutions for industrial, commercial and domestic electrical installations.
Websitesurgedevices.co.uk
AddressSurge Protection Devices Ltd, Johnson House, Watts Street, Oldham, OL9 9LQ
CityOldham
CountryUnited Kingdom
Map locationMap
Opening hoursOffice Hours: Monday-Friday 8.30-4.30pm
Times in Europe/London
As written on the website.
Phone01484 851747
Emailinfo@surgedevices.co.uk
Contact pagehttps://www.surgedevices.co.uk/contact/
Founded2006
LanguagesEnglish
Company number05920962
VAT number894 710200
Web shopWeb shop on WooCommerce: 109 products, £40–£744
CurrencyGBP
What they sell360 Range, Type 1 SPD Combined Lightning and Surge Arresters for TNC-S and TN-S Installatio, Type 2 SPD Surge Arresters for TNC-S and TN-S Installations, Type 1 SPD Lightning and Surge Arresters for TT Installations, Type 2 SPD Surge Arresters for TT Installations, Replacement Modules, Specials, BT, Phone, POE & CCTV Surge Protection Devices, Enclosures & Breakers, Protection of Photovoltaic / Solar Systems, Sale – Type 2, Sale – Type 1, Sale – Other
Number of products109
Product prices£40–£744
Last product update23 October 2026
Returns informationhttps://www.surgedevices.co.uk/returns-refund-policy/
Social profilesFacebook · LinkedIn · Instagram
Logohttps://www.surgedevices.co.uk/wp-content/uploads/2026/07/Surge-Protection.png
Imagehttps://www.surgedevices.co.uk/wp-content/uploads/2025/04/Surge-events-1024x768.jpg

About

At Surge Protection Devices Ltd, we believe that great technical solutions start with great people. Whilst our products protect some of the UK’s most critical installations, including commercial, industrial and public sector projects, we remain a close-knit, family-run business at heart. Our size allows us to do something many larger manufacturers struggle to achieve – provide genuine technical support from people who truly care about getting the right solution for every customer. Our reputation has been built on honesty, integrity and technical expertise.

Frequently asked questions

What is a Surge Protection Device?
A Surge Protection Device (SPD) is designed to protect electrical installations and equipment from transient overvoltages, commonly known as surges. These surges can be caused by nearby lightning strikes, switching operations within the electrical network, or faults on the power supply. By safely diverting excess voltage to earth, an SPD helps prevent damage to sensitive electrical and electronic equipment, reducing the risk of costly downtime, repairs and replacements.
What is a Surge?
A surge is a very short, sharp increase in the voltage in the electrical system. The voltage is essentially the pressure of the electrical system, so when this increases, it leads to electrical components being damaged within the installation. You won’t be aware of the surges when they occur, but over time they lead to the degradation of electrical components, which will shorten the lifespan of the electrical equipment in your installation, whether that’s a domestic dwelling, or commercial / industrial premesis.
Why does your home need a Surge Protection Device?
Modern homes are filled with valuable electronic equipment, most of which contain sensitive components that can be damaged in an instant by a surge. From smart TV’s, computers, gaming consoles, boiler controls, heat pumps, washing machines and LED lightning, today’s homes rely on technology more than ever before. Surges can lead to costly repairs, equipment replacement and, in some cases, the loss of irreplaceable memories such as family photos, videos and important documents stored on computers and connected devices. While many homeowners insure their possessions against theft and accidental
What about lightning?
Lightning strikes can generate powerful surges that travel through the electrical system, even when the strike occurs several miles away. For most installations, a Type 2+3 SPD provides effective protection against the surges commonly caused by nearby lightning strikes, switching events or power disturbances. However, when a building is fitted with an external lightning protection system (LPS) or is supplied by overhead power lines, a Type 1+2+3 SPD is required. These devices are specifically designed to withstand and safely discharge a high-energy surge and lightning impulse event, associated
What is a Type 1 Surge Protection Device?
A Type 1 Surge Protection Device is designed to protect electrical installations against lightning strikes. When and where is it Required? Under BS 7671 and BS EN 62305, a Type 1 SPD is strictly required at the origin of an installation under the following conditions: External Lightning Protection System (LPS): If the building is equipped with an external lightning protection system, BS EN 62305 takes precedence, making a Type 1 SPD mandatory at the origin and distribution boards that supply sub-circuits or equipment located outside the main structure—such as external EV charging stations or s
When and where is it Required?
Under BS 7671 and BS EN 62305, a Type 1 SPD is strictly required at the origin of an installation under the following conditions:
What is a Type 2 Surge Protection Device?
A Type 2 Surge Protection Device is the standard form of protection used in electrical installations to protect against transient overvoltages caused by indirect lightning strikes and everyday switching events. When and where is it Required? Type 2 SPDs are installed at main distribution boards or sub-distribution boards to safeguard the entire wiring infrastructure and downstream loads. A Type 2 SPD provides all the protection required at the board level where there is no external lightning protection system and no overhead supply Browse our range of Type 2 SPDs
How do I select the correct SPD ?
To correctly select an SPD, you can follow the following steps: 1) We need to select the type of SPD Main Incomer of the installation and it has an overhead supply – Type 1 Main Incomer of the installation and it has an external LPS – Type 1 Sub board and the installation has an overhead supply – Type 2 Sub board (internal circuits only) and the installation has an LPS – Type 2 Sub board (includes external circuits) and the installation has an LPS – Type 1 Sub board and the installation has no LPS and underground supply – Type 2 2) What is the earthing system TN/TNC/TNS/PME – CT1 or CT2 TT – C
Where should surge protection be installed?
To achieve full protection, SPDs must be installed at strategic points across an installation’s electrical infrastructure. Main Distribution Board Every installation requires primary protection installed as close as possible to the origin of the supply (e.g., consumer unit or main switchboard): Type 1 SPD: Required if there is an external LPS or overhead supply. Type 2 SPD: Required for standard installations without external lightning protection. Sub-Distribution Boards If an external LPS is installed on-site, and the DB supplied external equipment, these sub-boards require a Type 1 SPD. For
Does BS7671 require surge protection?
Yes. Under Section 443 of BS 7671 Wiring Regulations, surge protection is mandatory for the vast majority of electrical installations. Regulation 443.4.1 Requirements Protection against transient overvoltages shall be provided where the consequences of a surge could: Result in serious injury to, or loss of, human life. Result in significant financial or data loss. The Practical Position Because almost all modern domestic, commercial, and industrial distribution boards supply equipment that falls into these two categories—such as fire alarms, life-safety detection, or sensitive electronic and c
Can SPDs Be Omitted?
For all other installations not meeting the strict criteria above, an SPD is still required unless the person ordering the work formally declines the installation in writing and explicitly accepts the long-term risk to the wiring and equipment as tolerable.
How often should an SPD be replaced?
An SPD does not have a fixed calendar expiration date; instead, its lifespan depends on the frequency and intensity of the overvoltages it diverts to earth. Each time a transient overvoltage or switching surge occurs, these components divert energy to earth, undergoing a small amount of internal degradation in the process. Over time, repeated small surges or a single massive direct spike will cause the module to reach the end of its operational life. An SPD would only need replacing when the indication changes over on the module.
Can you test an SPD?
No. You should not electrically test an SPD. An SPD acts as a voltage-controlled variable resistor. Under normal operating voltages, it maintains high electrical resistance. When exposed to high voltage, its resistance drops instantaneously to establish a low-impedance path to earth. An electrical testing instrument (such as an insulation resistance tester or high-voltage flash tester) injects high DC voltages into the circuit. The SPD cannot distinguish between test voltage and a dangerous surge event. Consequently: The tester will yield false readings (e.g., failing an insulation resistance
Do solar PV systems require SPDs?
Yes. Solar photovoltaic (PV) systems require surge protection on both the AC and DC sides under BS 7671 Section 443.4, which applies equally to AC and DC electrical circuits. Common Misconceptions to Avoid Integrated Inverter Protection: Installers often assume an inverter with “built-in” surge protection removes the need for external SPDs. Many inverters only provide protection on their AC side or use basic varistors that do not satisfy the full product standards (BS EN 61643-31). Installers should request an official Certificate of Conformity from the manufacturer to confirm DC-side complian

Features

What they sell

Web shop on WooCommerce: 109 products, £40–£744. Sells: 360 Range, Type 1 SPD Combined Lightning and Surge Arresters for TNC-S and TN-S Installatio, Type 2 SPD Surge Arresters for TNC-S and TN-S Installations, Type 1 SPD Lightning and Surge Arresters for TT Installations, Type 2 SPD Surge Arresters for TT Installations, Replacement Modules, Specials, BT, Phone, POE & CCTV Surge Protection Devices, Enclosures & Breakers, Protection of Photovoltaic / Solar Systems, Sale – Type 2, Sale – Type 1, Sale – Other.

12 of 109 products, prices £40–£744, as published by the shop (read from the shop 18 h ago; the shop last changed its products 23 October 2026; last change seen here 18 h ago). Prices and stock change; the shop’s website has the current ones.

Verification

Unclaimed · Not verified by owner. Nobody has claimed this listing yet, so no fact has been confirmed by the business itself. Verification state: unclaimed.

Key facts on this card: 10 of 11; missing: Booking, order, menu or pricing link. AI-ready (at least 8 of 11 key facts filled in).

Is this your business? Claim this listing (free: prove you control the website, and the badge changes to “Verified by owner”). What claiming means.

Where these facts come from

Read from surgedevices.co.uk. Last checked 23 November 2026 (18 h ago); last changed 18 h ago; listed since 23 November 2026. Every listing is re-checked about every 7 days.

FactFound inPage
Namestructured data/
Summarypage metadata/
Aboutpage text/about/
Addresspage text/
Citypage text/
Phonepage text/
Emailpage text/
Opening hourspage text/
FAQspage text/about/faqs-about-spds/
Featurespage text/about/, /about/meet-the-team/
Languagespage metadata/, /contact/, /about/, /about/meet-the-team/, /about/faqs-about-spds/, /cpd-training/, /terms-of-service/, /returns-refund-policy/
Foundedpage text/about/
Logostructured data/
Imagepage metadata/
Social profilesstructured data/, /contact/, /about/, /about/meet-the-team/, /about/faqs-about-spds/, /cpd-training/, /terms-of-service/, /returns-refund-policy/
Contact pagepage text/
Company numberpage text/
VAT numberpage text/
Returns informationpage text/
Categorypage text/
Web shoppage metadata/
Shop platformpage metadata/
Shop statusshop platform data/wp-json/wc/store/v1/products
Number of productsshop platform data/wp-json/wc/store/v1/products
Last product updateshop platform data/wp-json/wc/store/v1/products
Product pricesshop platform data/wp-json/wc/store/v1/products
Currencyshop platform data/wp-json/wc/store/v1/products
What they sellshop platform data/wp-json/wc/store/v1/products
Countrypage text/

Recent checks

More in Shops & Retail

How to use this site as an agent

This page as Markdownhttps://aifindme.com/b/surge-protection-devices.md (or send Accept: text/markdown to this address)
This page as JSONhttps://aifindme.com/b/surge-protection-devices.json (or Accept: application/json)
This page as llms.txthttps://aifindme.com/b/surge-protection-devices/llms.txt
This page through the APIhttps://aifindme.com/api/v1/businesses/surge-protection-devices
Start herehttps://aifindme.com/agents: what a fact card guarantees, the three ways to query, rules and rate limits, freshness, how to add or correct a business. Long form: https://aifindme.com/for-ai-agents
Search APIGET https://aifindme.com/api/v1/businesses?q=…&category=…&city=…&kind=shop&verified=1&open=now · OpenAPI · documentation
MCP serverPOST https://aifindme.com/mcp (Streamable HTTP, no key): search_businesses, get_business, get_products, list_new_listings, list_categories, list_cities
Directory indexhttps://aifindme.com/llms.txt: every category and city with counts, and the latest listings · https://aifindme.com/llms-full.txt: one compact entry per listing
Agent skillhttps://aifindme.com/skills/aifindme/SKILL.md: when and how to use this directory and how to cite it (Agent Skills format)
ViewsAdd ?view=ai or ?view=human to any address. Both carry the same facts and links; only the presentation differs.