Facts as published by the shop. Prices and stock change; the shop’s website has the current ones.

About

CLIMATEIQ - The Premier Platform ForManaging Complex Climate Environments Stop Throwing Labor at a Process Problem. The Satellite Changes the Equation. The Standard in Water-Powered Nutrient DosingTrusted by Growers Who Demand Consistency

Services

  • Learning Center
  • Shop by Category

Prices

Quest DehumidifiersFrom $2,299.95
Prokure Starter Pack$512.61
From$99.79
Sale Price$75.00

Prices as shown on the website when it was last read; the business may have changed them since.

Frequently asked questions

How often should I replace calibration buffer solutions?

Replace pH buffer solutions every 6 months after opening, or sooner if the solution appears discolored, has visible contamination, or smells different from fresh buffer. Contaminated or degraded buffer produces inaccurate calibration that offsets every subsequent measurement. Store buffer in a cool, dark location with the cap tightly sealed between uses. Never pour used buffer back into the original bottle - contamination from the probe tip or residual nutrient solution in the calibration cup degrades the remaining buffer.

Why should I never store a pH probe in distilled water?

pH probes use an internal electrolyte solution (typically potassium chloride, KCl) that must remain concentrated to function correctly. Distilled or RO water has virtually zero ion content - when a probe is stored in distilled water, osmosis draws KCl out of the probe through the reference junction, depleting the internal electrolyte and degrading probe response and accuracy over time. Always store pH probes in probe storage solution (3M KCl or the manufacturer's recommended storage solution) that matches the ionic strength of the internal electrolyte, preventing osmotic depletion.

What EC calibration solution should I use for hydroponic nutrient programs?

For hydroponic growing: 1,413 microsiemens/cm (1.413 mS/cm) calibration solution covers the EC range used in most growing programs (1.0-3.5 mS/cm for most crops) and is the most common standard. Some EC meters calibrate at 12,880 microsiemens/cm (12.88 mS/cm) for applications requiring accuracy at higher EC levels; verify which standard your meter requires from the documentation before purchasing calibration solution - using the wrong concentration provides an inaccurate calibration reference.

How do I clean a pH probe that is giving slow or erratic readings?

Slow response and erratic readings are most often caused by contamination on the probe tip. Cleaning procedure: (1) Rinse the probe with clean water; (2) Soak the tip in pH probe cleaning solution for 10-15 minutes - commercial probe cleaner dissolves protein and biofilm deposits that accumulate from nutrient solutions; (3) Rinse again with clean water; (4) Soak in storage solution for 30 minutes to rehydrate the reference junction before recalibrating. If slow response persists after cleaning, the probe may be at the end of its service life and requires replacement.

Can I use the same calibration solution multiple times?

No - pour fresh calibration solution into a clean calibration cup for each calibration session and discard the used solution afterward. Re-using calibration solution from previous sessions risks contaminating the buffer with nutrient residue from the probe tip, progressively changing the buffer's actual pH value and producing inaccurate calibrations. Buffer solution is inexpensive; using fresh solution for every calibration protects the accuracy of every subsequent measurement.

Do I need a water filter for hydroponics?

It depends on your water source quality and growing approach. For growers using precise nutrient programs in coco coir, rockwool, or recirculating hydroponics where consistent EC and nutrient ratios matter, RO filtration provides the cleanest starting point and eliminates tap water variability as a confounding factor. For growers in areas with very soft tap water (under 100 ppm TDS), the mineral contribution from tap water is small enough that building nutrient programs around it is practical. For growers using organic or living soil programs, removing chlorine and chloramine through carbon fi

How does reverse osmosis filtration work?

Reverse osmosis forces water through a semi-permeable membrane under pressure. The membrane allows water molecules to pass through while rejecting dissolved ions, minerals, and contaminants above a certain molecular size. Rejected material is flushed away in a waste stream; purified water passes through and collects in a holding tank or flows directly to the irrigation system. A complete RO system typically uses a sediment pre-filter (removes particulate that would foul the membrane), a carbon block pre-filter (removes chlorine and chloramine that would degrade the membrane), the RO membrane i

How much water does an RO system waste?

Standard RO membranes produce 1 gallon of purified water for every 2-4 gallons of input water (25-50% efficiency), with the remainder as reject water carrying the concentrated dissolved solids. High-efficiency RO systems (GrowoniX, some AXEON models) achieve 1:1 to 2:1 reject-to-permeate ratios through recirculating reject water design or high-efficiency membranes - meaningfully reducing water waste in water-conscious operations. For small hobby systems, waste water ratios are typically acceptable. For large commercial operations producing hundreds of gallons of RO water per day, high-efficien

What is the difference between Hydro Logic and GrowoniX RO systems?

Hydro Logic produces a range of RO systems from countertop and under-sink hobby units (50-200 GPD) to mid-scale commercial systems - known for accessible pricing, widely available replacement filters, and ease of installation without specialized plumbing knowledge. Their Stealth RO and Evolution series are popular entry-to-mid range options for home and small commercial grows. GrowoniX focuses on high-efficiency commercial RO systems designed for large-volume production where water conservation and throughput are the priorities - their systems feature higher efficiency membranes (lower waste r

Does tap water need to be treated before using in a hydroponic system?

It depends on your municipality's water treatment method and your growing system type. If your water uses standard chlorination (most common), letting the water sit in an open reservoir with air stones running for 24 hours removes most chlorine through aeration. If your water uses chloramine (check your annual water quality report), aeration will not remove it - you need a dedicated dechlorinator that specifically addresses chloramine. For living soil programs where beneficial microbial populations are the foundation of the system, treating for both chlorine and chloramine is recommended regar

How do I know if my water has chlorine or chloramine?

Check your municipality's annual Consumer Confidence Report (CCR), which all US public water systems are required to provide - it lists the disinfection method used. You can also call your water utility and ask directly. A simple field test: put a drop of your tap water on a pet store chlorine/chloramine test strip - strips that show positive for chlorine after 24 hours of aeration indicate chloramine, since free chlorine would have dissipated. Many municipalities have switched from chlorine to chloramine over the past decade as chloramine provides longer-lasting protection in distribution sys

What is pH up and pH down and when do I use them?

pH up and pH down are water treatment solutions that adjust the acidity of irrigation water and nutrient solution to the target pH range for your growing system. pH down (typically phosphoric acid or citric acid) lowers pH; pH up (typically potassium hydroxide or potassium carbonate) raises pH. Most tap water in the US is pH 7-8, and most hydroponic nutrient solutions need to be brought down to pH 5.5-6.5 for optimal nutrient availability. Add pH down after mixing your nutrient solution, in small increments, measuring after each addition until you reach your target. pH adjustment is one of the

What is a liquid compost digester and how does it work?

A liquid compost digester (Power Knot LCD series) uses accelerated biological decomposition to convert organic waste material into liquid effluent. Plant material is loaded into the machine along with a bioenzyme accelerant. The machine's heating element maintains optimal temperature for microbial activity (typically 130-140 degrees F), agitation ensures even decomposition throughout the load, and aeration provides the oxygen that aerobic decomposition requires. The resulting liquid effluent - essentially a dilute compost liquid - discharges through a drain connection to the wastewater system.

What is required for compliant waste disposal in a licensed growing facility?

Waste disposal requirements vary significantly by state and local jurisdiction. Most regulated markets require that plant waste be rendered unrecognizable (cannot be identified as the plant species) and unusable before disposal. Common compliant pathways include: rendering unrecognizable through grinding/shredding and mixing with other waste streams, liquid composting via biological digestion to liquid effluent, on-site composting with approved turning and temperature monitoring, and licensed waste hauler removal. Verify your specific jurisdiction's waste disposal requirements with your regula

What size liquid digester do I need for my facility?

Power Knot LCD models are sized by daily processing capacity: LCD-50 (50 lb/day), LCD-70 (70 lb/day), LCD-100 (100 lb/day), LCD-200, LCD-300, and LCD-1000. Calculate your daily average biomass waste volume (trim, stalks, roots, and waste plant material from harvest cycles) and select a model with capacity above your peak daily waste production - running a digester consistently at maximum capacity reduces machine life and processing efficiency. For large commercial facilities producing hundreds of pounds of waste daily, contact 888-815-9763 to discuss LCD-1000 commercial configurations and mult

Features

Free consultation

Is this your business? Claim it

This listing is unclaimed: it was created automatically from hydrobuilder.com, and nobody has verified it yet. Claiming is free and takes a few minutes: you prove you control the website, and the badge changes to “Verified by owner”. Facts you confirm are trusted more by the AI assistants that read this page.

Key facts on this card: 10 of 1191% complete

Missing: Opening hours.

Claim this listing What claiming means

Where these facts come from

Read from hydrobuilder.com. Last checked 22 min ago; last changed 22 min ago. Every listing is re-checked about every 7 days. Nobody has claimed this listing yet, so no fact has been confirmed by the business itself.

Show the source of each fact
FactFound inPage
Namestructured data/
Summarystructured data/
Aboutpage text/pages/about
Addressstructured data/
Citystructured data/
Regionstructured data/
Postal codestructured data/
Countrystructured data/
Phonestructured data/
Emailpage text/
Servicespage text/collections/water-conditioners-solutions
Pricespage text/, /pages/contact, /pages/grow-diagnostics-plant-health-testing-services, /collections/calibration-cleaning-solutions, /collections/water-filtration-and-treatment, /collections/water-conditioners-solutions, /collections/harvest-waste-solutions, /collections/innovative-solutions, /pages/about
FAQsstructured data/collections/calibration-cleaning-solutions, /collections/water-filtration-and-treatment, /collections/water-conditioners-solutions, /collections/harvest-waste-solutions
Featurespage text/pages/grow-diagnostics-plant-health-testing-services
Languagespage metadata/, /pages/contact, /pages/grow-diagnostics-plant-health-testing-services, /collections/calibration-cleaning-solutions, /collections/water-filtration-and-treatment, /collections/water-conditioners-solutions, /collections/harvest-waste-solutions, /collections/innovative-solutions, /pages/about
Foundedstructured data/
Logostructured data/
Imagepage metadata/
Social profilesstructured data/, /pages/contact, /pages/grow-diagnostics-plant-health-testing-services, /pages/about
Order linkpage text/pages/grow-diagnostics-plant-health-testing-services
Contact pagepage text/
Pricing pagepage text/
Shipping informationpage text/
Returns informationpage text/pages/contact
Categorypage text/
Web shoppage metadata/
Shop platformpage metadata/
Currencypage metadata/

Recent checks

  • 22 min ago Added to the directory

Report this listing · Ask for removal

For AI assistants and agents

schema.org data is embedded in this page. Facts last checked 23 November 2026.