Labfacility: products, shipping and shop facts
Shops & Retail · United Kingdom · Web shop on Magento · Unclaimed · Not verified by owner · facts last read 28 November 2026 · read from labfacility.com.
Facts
| Name | Labfacility |
|---|---|
| Category | Shops & Retail |
| Summary | Resistance Thermometer Theory And Practice |
| Website | labfacility.com |
| Country | United Kingdom |
| Open now | Closed now · opens Mon 08:00 · times in Europe/London |
| Opening hours | Mon–Thu: 08:00–17:00 Fri: 08:00–12:30 Sat, Sun: Closed |
| Phone | 00441243871280 |
| sales@labfacility.com | |
| Contact page | https://www.labfacility.com/contact |
| Menu link | https://www.labfacility.com/ |
| Founded | 1971 |
| Payment methods | PayPal, Apple Pay, Google Pay, Klarna, iDEAL |
| Languages | English |
| Web shop | Web shop on Magento |
| Return period | 30 days |
| Shipping information | https://www.labfacility.com/postage-delivery |
| Returns information | https://www.labfacility.com/returns-policy |
| Social profiles | LinkedIn · YouTube · Facebook · X · Instagram |
About
Labfacility are the UK's leading manufacturer of Temperature Sensors, Thermocouple Connectors and associated Temperature Instrumentation and stockists of Thermocouple Cables. The Company has been trading since 1971 and is ISO 9001 accredited. We have two UK sites – West Sussex and South Yorkshire and export to over 85 countries, Shipments are made to world-wide destinations on a daily basis. In addition to the stocked items, Labfacility also offers bespoke Temperature Sensors. We are specialists in the design and manufacture of custom-built temperature sensors at our 18,000 square foot Yorkshire plant located in Dinnington.
Prices
| Zone 1 | £12 |
|---|---|
| Zone 2 | £59 |
| Zone 3 | £73 |
| Zone 4 | £88 |
| Zone 5 | £89 |
| Zone 6 | £113 |
Frequently asked questions
- 1. What is the difference between a Mineral Insulated (MI) and a fabricated sheath?
- 2. How accurately can I measure temperature using a standard sensor?To published, internationally specified tolerances as standard, typically ± 2.5°C for popular thermocouples, ±0.5°C for PRT. Higher accuracy sensors can be supplied to order, e.g. ±0.5°C for type T thermocouple, ±0.2°C for PRT. All of these values are temperature dependent. A close tolerance, 4-wire PRT will give best absolute accuracy and stability.
- 2. How accurately can I measure temperature using a standard sensor?
- 3. How do I choose between a thermocouple and a PRT?Mainly on the basis of required accuracy, probe dimensions, speed of response and the process temperature.
- 3. How do I choose between a thermocouple and a PRT?
- 4. My thermocouple is sited a long way from my controller, is this a problem?It could be; try to ensure a maximum sensor loop resistance of 100 Ohms for thermocouples and 4-wire PRTs. Exceeding 100 Ohms could result in a measurement error. Note By using a 4-20mA transmitter near the sensor, cable runs can be much longer and need only cheaper copper wire. The instrument must be suitable for a 4-20mA input though.
- 4. My thermocouple is sited a long way from my controller, is this a problem?
- 5. What is the difference between a RTD and PRT sensor?Nothing. RTD means resistance thermometer detector (the sensing element) and PRT means Platinum resistance thermometer (the whole assembly) i.e. a PRT uses a RTD!
- 5. What is the difference between a RTD and PRT sensor?
- 6. What is a Pt100?An industry standard Platinum RTD with a value of 100 Ohms @0°C to IEC751; this is used in the vast majority of PRT assemblies in most countries.
- 6. What is a Pt100?
- 7. Should I choose a Type K or Type N thermocouple?Generally, Type N is more stable and usually lasts longer than Type K; N is a better choice for high temperature work depending on the choice of sheath material.
- 7. Should I choose a Type K or Type N thermocouple?
- 8. Does it matter what type of steel I specify for the thermocouple sheath?Often no, sometimes yes. In some cases, reliability depends on the ideal choice of material.
- 8. Does it matter what type of steel I specify for the thermocouple sheath?
- 9. Are there other types of temperature sensor apart from thermocouple and PRT Types?Several, but these two groups are the most common. Alternatives include thermistors, infra-red (non-contact), conventional thermometers (stem & dial types) and many others.
- 9. Are there other types of temperature sensor apart from thermocouple and PRT Types?
- 10. Why are so many different types of thermocouple used?They have been developed over many years to suit different applications world-wide.
- 10. Why are so many different types of thermocouple used?
- 11. What is a duplex sensor?One with two separate sensors in a single housing
- 11. What is a duplex sensor?
- 12. Why use a thermowell?To protect the sensor from the process medium and to facilitate its replacement if necessary.
- 12. Why use a thermowell?
- 13. I use many thermocouples in testing and experiments, can I make my own thermocouple junctions?Yes, using a benchtop welder and fine thermocouple wires – it is easy and inexpensive to make unsheathed thermocouples.
- 13. I use many thermocouples in testing and experiments, can I make my own thermocouple junctions?
- 14. Why should I use actual thermocouple connectors instead of ordinary electrical connectors?Good quality thermocouple connectors use thermocouple alloys, polarized connections and colour coded bodies to guarantee perfect, error-free interconnections.
- 14. Why should I use actual thermocouple connectors instead of ordinary electrical connectors?
- 15. Why offer 2,3 or 4 wire PRT probes?Because all 3 are encountered. Two-wire should be avoided, three-wire is widely used and four-wire gives optimum accuracy. Your instrument will be configured for 2,3 or 4 wire.
- 15. Why offer 2,3 or 4 wire PRT probes?
- 16. For thermocouple cable and connectors, why are there two colours available for the same calibration?Since December 1998, the International colour code to IEC 60584-3 should be observed.
Features
- Wi-Fi
- Delivery
What they sell
Web shop on Magento.
Verification
Unclaimed · Not verified by owner. Nobody has claimed this listing yet, so no fact has been confirmed by the business itself. Verification state: unclaimed.
Key facts on this card: 10 of 11; missing: Location or service area. A field with a value was not checked by us. No field was entered by the owner.
Known problems: none found by our automatic checks, which find some and not all.
Is this your business? Claim this listing (free: a code by email is often enough, the claim page says which addresses work; or proof on the website). What claiming means.
Where these facts come from
Read from labfacility.com. Last read 28 November 2026 (3 h ago); last changed 3 h ago; listed since 28 November 2026. Every listing is re-checked regularly.
| Fact | Found in | Page |
|---|---|---|
| Name | page metadata | / |
| Summary | page metadata | /resistance-thermometer-theory-and-practice |
| About | page text | / |
| Phone | page text | / |
| page text | / | |
| Opening hours | page text | /contact |
| Opening hours (structured) | page text | /contact |
| Prices | page text | /postage-delivery |
| FAQs | page text | /faq |
| Features | page text | /, /contact, /labfacility, /resistance-thermometer-theory-and-practice, /thermocouple-theory-and-practice, /faq, /postage-delivery |
| Payment methods | page text | /, /contact, /labfacility, /resistance-thermometer-theory-and-practice, /thermocouple-theory-and-practice, /terms-conditions, /returns-policy, /faq, /postage-delivery |
| Languages | page metadata | /, /contact, /labfacility, /resistance-thermometer-theory-and-practice, /thermocouple-theory-and-practice, /terms-conditions, /returns-policy, /faq, /postage-delivery |
| Founded | page text | / |
| Social profiles | page text | /, /contact, /labfacility, /resistance-thermometer-theory-and-practice, /thermocouple-theory-and-practice, /terms-conditions, /returns-policy, /faq, /postage-delivery |
| Menu link | page text | / |
| Contact page | page text | / |
| Return period | page text | /returns-policy |
| Shipping information | page text | / |
| Returns information | page text | / |
| Category | page text | / |
| Web shop | page metadata | / |
| Shop platform | page metadata | / |
| Country | website signals | labfacility.com/ |
Recent checks
- 3 h ago: Added to the directory
How often this listing is read
No visit counted yet by people, or by the AI systems and search engines we count. We started counting on 25 November 2026.
More in Shops & Retail
Links
- Markdown fact card · JSON fact card (every fact with its source) · llms.txt · API · products API · documentation, OpenAPI and the MCP server
- Report this listing · Remove this listing
How to use this site as an agent
| This page as Markdown | https://aifindme.com/b/labfacility.md (or send Accept: text/markdown to this address) |
|---|---|
| This page as JSON | https://aifindme.com/b/labfacility.json (or Accept: application/json) |
| This page as llms.txt | https://aifindme.com/b/labfacility/llms.txt |
| This page through the API | https://aifindme.com/api/v1/businesses/labfacility |
| Start here | https://aifindme.com/agents: what a fact card tells you, the three ways to query, rules and rate limits, freshness, how to add or correct a listing. Long form: https://aifindme.com/for-ai-agents |
| Search API | GET https://aifindme.com/api/v1/businesses?q=…&category=…&city=…&kind=shop&verified=1&open=now · OpenAPI · documentation |
| MCP server | POST https://aifindme.com/mcp (Streamable HTTP, no key): search_businesses, get_business, get_products, list_new_listings, list_categories, list_cities |
| Directory index | https://aifindme.com/llms.txt: every category and the biggest cities with counts, and the latest listings · https://aifindme.com/llms-full.txt: one compact entry for each of the most complete listings (about a thousand) |
| Agent skill | https://aifindme.com/skills/aifindme/SKILL.md: when and how to use this directory and how to cite it (Agent Skills format) |
| Views | Add ?view=ai or ?view=human to any address. Both carry the same facts and links; the presentation differs. |